Connecting
6.3 System integration
SIMOTICS S-1FT2 synchronous motors for SINAMICS S120
Operating Instructions, 07/2021, A5E50610821B AB
65
For connector size M40
①
SPEED-CONNECT connector, size M40
②
Terminal for the cable shield
③
Cable shield
④
Connection diagram
U; V; W = power cables, 1.5 mm
2
, each cable with separate shielding
BD1+ and BD2- = brake cable without lettering, 1.5 mm
2
, shielded together
PE = protective conductor
⑤
Cable shield
⑥
Conductor designations
⑦
Recommended length of the cable ends: 105 mm
Lock the round connector properly on the motor
Information on locking is provided in Chapter "Handling the quick-action locking (Page 66)".