Fundamental safety instructions
1.4 Residual risks of power drive systems
SIMOTICS S-1FT2 synchronous motors for SINAMICS S120
Operating Instructions, 07/2021, A5E50610821B AB
17
1.4
Residual risks of power drive systems
When assessing the machine- or system-related risk in accordance with the respective local
regulations (e.g., EC Machinery Directive), the machine manufacturer or system installer
must take into account the following residual risks emanating from the control and drive
components of a drive system:
1.
Unintentional movements of driven machine or system components during commissioning,
operation, maintenance, and repairs caused by, for example,
–
Hardware and/or software errors in the sensors, control system, actuators, and cables
and connections
–
Response times of the control system and of the drive
–
Operation and/or environmental conditions outside the specification
–
Condensation/conductive contamination
–
Parameterization, programming, cabling, and installation errors
–
Use of wireless devices/mobile phones in the immediate vicinity of electronic
components
–
External influences/damage
–
X-ray, ionizing radiation and cosmic radiation
2.
Unusually high temperatures, including open flames, as well as emissions of light, noise,
particles, gases, etc., can occur inside and outside the components under fault conditions
caused by, for example:
–
Component failure
–
Software errors
–
Operation and/or environmental conditions outside the specification
–
External influences/damage
3.
Hazardous shock voltages caused by, for example:
–
Component failure
–
Influence during electrostatic charging
–
Induction of voltages in moving motors
–
Operation and/or environmental conditions outside the specification
–
Condensation/conductive contamination
–
External influences/damage
4.
Electrical, magnetic and electromagnetic fields generated in operation that can pose a risk to
people with a pacemaker, implants or metal replacement joints, etc., if they are too close
5.
Release of environmental pollutants or emissions as a result of improper operation of the
system and/or failure to dispose of components safely and correctly
6.
Influence of network-connected communication systems, e.g. ripple-control transmitters or
data communication via the network
For more information about the residual risks of the drive system components, see the
relevant sections in the technical user documentation.