![Siemens SIMOTICS M-1FE2 Скачать руководство пользователя страница 72](http://html.mh-extra.com/html/siemens/simotics-m-1fe2/simotics-m-1fe2_configuration-manual_379035072.webp)
Motor components and options
4.1 Motor components
SIMOTICS M-1FE2 built-in motors
70
Configuration Manual, 05/2021, A5E50494252B AB
Biocide
Closed cooling circuits with soft water are susceptible to microbes.
•
If possible, use chlorinated potable water.
Note
Compatibility of coolant additives
Biocides and Antifrogen N must not be mixed.
•
If no chlorinated potable water is available, add, for example Antifrogen N or a biocide, to
the potable water.
Antifrogen N acts like a biocide for a minimum concentration > 20%.
•
Conduct a water analysis at least annually to determine the type and concentration of
microbes.
The following microbes can occur in practice:
–
Bacteria that cause the formation of slime
–
Corrosive bacteria
–
Bacteria that cause deposits of iron
•
Add a biocide that counters the determined microbes to the cooling water.
The manufacturer's recommendations must be followed in regard to the dosage and
compatibility with any inhibitor used.
Содержание SIMOTICS M-1FE2
Страница 1: ......
Страница 2: ......
Страница 8: ...Introduction SIMOTICS M 1FE2 built in motors 6 Configuration Manual 05 2021 A5E50494252B AB ...
Страница 12: ...Table of contents SIMOTICS M 1FE2 built in motors 10 Configuration Manual 05 2021 A5E50494252B AB ...
Страница 150: ...Dimension drawings SIMOTICS M 1FE2 built in motors 148 Configuration Manual 05 2021 A5E50494252B AB ...
Страница 152: ...Environmental compatibility SIMOTICS M 1FE2 built in motors 150 Configuration Manual 05 2021 A5E50494252B AB ...
Страница 161: ......
Страница 162: ......