8.7
Switching on again after an emergency switching-off
● Check the machine before recommissioning the driven machine after an Emergency Off.
● Eliminate all the causes that have led to the emergency off
8.8
Stoppages
The stoppage is a shutdown for a period of time, during which the machine is stopped but
remains at the location of use.
Under normal ambient conditions, e. g. the stopped machine is not exposed to any vibration,
no increased level of corrosion, etc. in general, the following measures are necessary during
stoppages.
8.8.1
Avoidance of condensation or formation of condensation within the machine
● If the controller does not do this automatically, switch on any anti-condensation heating
during stoppages. This will avoid the formation of condensation.
● Observe the specifications on the anti-condensation heating plate in this regard.
8.8.2
Avoidance of frost and corrosion damage to the air-to-water heat exchanger
● For avoidance of frost and corrosion damage completely drain the water from the air-to-
water cooler. Then blow air through it to dry it.
● If the cooler cannot be drained because standby capability is required at short notice,
protect the cooling circuit against frost and corrosion damage. To do this, add suitable
additives to the cooling water.
NOTICE
Diminished heat conduction
These additives may affect the heat transport capability. Operate the motor only with the
contractually agreed water quality.
For avoidance of deposits, the cooling water circuit must then be kept running. So as to be
certain of excluding the possibility of formation of condensation within the machine, the anti-
condensation heating should also remain switched on.
● Comply with the cooler manufacturer's instructions for cooling system servicing in the
operating instructions.
Operation
8.7 Switching on again after an emergency switching-off
SIMOTICS HV M 1RN76308PR900CG0-Z
80
Operating Instructions 07/2018
Содержание SIMOTICS HV M
Страница 2: ...03 07 2018 13 28 V3 00 ...
Страница 22: ...Description SIMOTICS HV M 1RN76308PR900CG0 Z 22 Operating Instructions 07 2018 ...
Страница 58: ...Assembly 5 5 Complete the installation work SIMOTICS HV M 1RN76308PR900CG0 Z 58 Operating Instructions 07 2018 ...
Страница 86: ...Operation 8 11 Faults SIMOTICS HV M 1RN76308PR900CG0 Z 86 Operating Instructions 07 2018 ...
Страница 108: ...Maintenance 9 2 Corrective Maintenance SIMOTICS HV M 1RN76308PR900CG0 Z 108 Operating Instructions 07 2018 ...
Страница 120: ...Disposal 11 4 Disposal of components SIMOTICS HV M 1RN76308PR900CG0 Z 120 Operating Instructions 07 2018 ...
Страница 122: ...Service and Support SIMOTICS HV M 1RN76308PR900CG0 Z 122 Operating Instructions 07 2018 ...
Страница 128: ...Quality documents SIMOTICS HV M 1RN76308PR900CG0 Z 128 Operating Instructions 07 2018 ...
Страница 130: ...Additional documents SIMOTICS HV M 1RN76308PR900CG0 Z 130 Operating Instructions 07 2018 ...
Страница 135: ......