R
R
R
R
SIEMENS
Figure 3-1
Schematic of the rating plate
Table 3-2
Data on the rating plate
Item Description
Item Description
(1)
Type of motor
(15)
Rated power [kW or HP]
(2)
Order number
(16)
Rated efficiency factor
(3)
Identifier of the motor series
(17)
Rated speed [rpm]
(4)
Serial number
(18)
Rated frequency [Hz]
(5)
Weight
(19)
Efficiency class (IE code) or efficiency ac‐
cording to IEEE112B or empty
(6)
Degree of protection
(20)
Efficiency according to IEC/EN 60034-2-1
or current at service factor power
(7)
Type of construction
(21)
Motor design (converter or mains motor)
(8)
Permissible ambient temperature range
(22)
Line voltage/frequency
(9)
Thermal class of the insulation system
(23)
Optional additional data (e.g. service fac‐
tor, design and code letter, amount of cool‐
ing water and intake temperature, etc.)
(10)
Thermal class of the utilization
(24)
Country of manufacture and location
(11)
Maximum speed [rpm]
(25)
Certification mark for UL/CSA + file number
(optional)
(12)
Standards
(26)
Certificate number(s) for Ex motors for
Zone 2 (optional)
Description
SIMOTICS FD 1LH1
Operating Instructions 01/2019
23
Содержание SIMOTICS FD 1LH1
Страница 2: ...23 01 2019 19 26 V11 01 ...
Страница 28: ...Description SIMOTICS FD 1LH1 28 Operating Instructions 01 2019 ...
Страница 72: ...Assembly 5 5 Connecting the cooling water supply SIMOTICS FD 1LH1 72 Operating Instructions 01 2019 ...
Страница 122: ...Operation 8 10 faults SIMOTICS FD 1LH1 122 Operating Instructions 01 2019 ...
Страница 140: ...Maintenance 9 2 Corrective Maintenance SIMOTICS FD 1LH1 140 Operating Instructions 01 2019 ...
Страница 162: ...Disposal 11 5 Disposal of components SIMOTICS FD 1LH1 162 Operating Instructions 01 2019 ...
Страница 164: ...Service and Support SIMOTICS FD 1LH1 164 Operating Instructions 01 2019 ...
Страница 168: ...Quality documents SIMOTICS FD 1LH1 168 Operating Instructions 01 2019 ...
Страница 173: ......