E50417-K1074-C299-A1
Safety
according IEC/EN 61010, part 1
(VDE 0411 part 1)
Overvoltage category
III
Pollution degree
2
Fire resistance class of housing
V0 according to UL94
Voltage test (type test)
10Base-T Ports vs. power supply
U = 5.2 kV DC / 1 min
Impulse voltage according to IEC 60255-5 (type test)
5 kV
Voltage test (routine test)
10Base-T Ports vs. power supply
U = 3.1 kV DC / 2 s
Protection class
for the device
IP 40
for persons
IP 2x
Isolation of inputs and outputs
Power supply vs. 10Base-T Ports
double or reinforced
Electromagnetic compatibility
Emitted interference according to IEC/EN 61000-6-4
Interference field strength according to EN 55011/CISPR11 Class A
Radio interference voltage according to EN 55011/CISPR11 Class A
Immunity to interference according to IEC/EN 61000-6-2
Interference immunity to electromagnetic fields
according to IEC/EN 61000-4-3
10 V/m
Static electricity discharge
according to IEC/EN 61000-4-2
8 kV
Fast transients/burst
according to IEC/EN 61000-4-4
2 kV
Line conducted HF according to IEC/EN 61000-4-6
10 V
Impulse voltage/surge according to IEC/EN 61000-4-5
1/2 kV
Warning
The SIMEAS-Hub is a build-in device and must therefore be installed on
a switchboard or in a control cabinet. After installation, it is important
that all terminals are properly covered to prevent accidental contact with
energized parts.
Содержание SIMEAS-Hub 7KE6000-8AD /CC
Страница 22: ...Deutsch SIMEAS Hub 22 E50417 K1074 C299 A1 Maßbilder Bild 3 Maßbilder des SIMEAS Hub ...
Страница 26: ...Deutsch SIMEAS Hub 26 E50417 K1074 C299 A1 ...
Страница 46: ...English SIMEAS Hub 46 E50417 K1074 C299 A1 Dimensions Figure 6 Dimension drawings of the SIMEAS Hub ...
Страница 50: ...English SIMEAS Hub 50 E50417 K1074 C299 A1 ...
Страница 51: ...SIMEAS Hub SIMEAS Hub E50417 K1074 C299 A1 51 ...