System extensions
8.2.2
Connecting up the cables (more than 16 video outputs)
1.
Use the label sticker provided to correctly number video inputs 113 to 240 on
the extension bay.
2.
Connect the
SysLink
socket on the basic unit to the
SysLink Input
socket on
the extension bay using the Syslink cable (identifiable by Syslink markings).
3.
Unplug all the video input cables from video input 97 onward on the basic unit
and plug them into the same input numbers on the extension bay.
4.
Connect video outputs 1 to 32 on the extension bay to video outputs L1 to
L32 (the two top rows) on the basic unit.
Fig. 25
Circuit diagram for the basic and extension bays
8.2.3
Extension to a maximum of 240 video inputs
1.
Allocate a number to each additional video input module using the DIP switch
on the module to indicate the sequence of the modules from the bottom
upwards. The bottom module is number 1, the top module number 7.
Video input module
DIP switch setting
Video inputs in a 16
video output
configuration
Video inputs in a 32
video output
configuration
n.a.
n.a.
113 –128
97 – 112
1
0001
129 – 144
113 –128
2
0010
145 – 160
129 – 144
3
0011
161 –- 176
145 – 160
4
0100
177 – 192
161 –- 176
5
0101
193 – 208
177 – 192
6
0110
209 – 224
193 – 208
7
0111
224 – 240
209 – 224
Tab. 9
Video input module address allocation on the extension bay
2.
Each module must be inserted in the lowest available slot.
3.
Screw the module to the rear cover of the SIMATRIX NEO.
40
Siemens AB
Security Products