Program
6.5 Technical specifications of the blocks
Counter module FM 450-1
Manual, 02/2014, A5E03648739-02
49
Name
Declaration type
Data type
Meaning
The user...
The block...
RES_SYNC
IN-OUT
BOOL
Delete "synchronization"
status bit
sets
queries and
resets this
RES_ZERO
IN-OUT
BOOL
Reset status bits for zero
crossing, overflow,
underflow and comparator or
measurement end
sets
queries and
resets this
Processing jobs
You initiate a job for the FM 450-1 by means of the L_DIRECT, L_PREPAR, T_CMP_V1,
T_CMP_V2, RES_SYNC, RES_ZERO, OT_ERR_A and GATE_STP FC parameters.
Depending on the job you must enter the load value or a comparison value into the instance
DB prior to the calling the FC.
A set in/out parameter (L_DIRECT, L_PREPAR, T_CMP_V1, T_CMP_V2, RES_SYNC and
RES_ZERO) is deleted again by the FC CNT_CTRL after the job has been completed. This
enables you to recognize that the job has been completely executed by the FM 450-1 and, if
necessary, to evaluate this information in the user program.
Startup characteristics
As soon as the FC CNT_CTRL identifies a startup (CPU or FM startup), a pending job is
deferred and the startup is acknowledged. Any job you have already initiated is carried out
once the startup is finished and is therefore not lost.
Error Messages
If an operator error occurred when the FC is called, it is reported in the OT_ERR parameter.
You can read the error information in the DB 1 (variable OT_ERR_B). Thereafter you can
acknowledge the operator error with the OT_ERR_A parameter. No new operator error will
be reported until you have acknowledged the previous one.
Содержание simatic s7-400 FM 450-1
Страница 8: ...Table of contents Counter module FM 450 1 8 Manual 02 2014 A5E03648739 02 ...
Страница 18: ...Product Overview 1 5 The FM 450 1 software Counter module FM 450 1 18 Manual 02 2014 A5E03648739 02 ...
Страница 40: ...Wiring 4 4 Module status after power is switched on Counter module FM 450 1 40 Manual 02 2014 A5E03648739 02 ...
Страница 54: ...Program 6 5 Technical specifications of the blocks Counter module FM 450 1 54 Manual 02 2014 A5E03648739 02 ...
Страница 102: ...Encoder signals and their evaluation 9 5 Signal evaluation Counter module FM 450 1 102 Manual 02 2014 A5E03648739 02 ...
Страница 114: ...Errors and diagnostics 11 5 Operator error Counter module FM 450 1 114 Manual 02 2014 A5E03648739 02 ...
Страница 120: ...Spare parts Counter module FM 450 1 120 Manual 02 2014 A5E03648739 02 ...
Страница 122: ...References Counter module FM 450 1 122 Manual 02 2014 A5E03648739 02 ...
Страница 126: ...Glossary Counter module FM 450 1 126 Manual 02 2014 A5E03648739 02 ...
Страница 130: ...Index Counter module FM 450 1 130 Manual 02 2014 A5E03648739 02 ...