![Siemens Simatic RF382R Scanmode Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/siemens/simatic-rf382r-scanmode/simatic-rf382r-scanmode_compact-operating-instructions_374418016.webp)
SIMATIC RF382R Scanmode
16
J31069-D0214-U001-A4-7618, 10/2013
6GT2801-3AB20-0AX0
Maximum data transmission rate
transponder
↔
reader (read)
1500 byte/s
Functions
Read transponder;
Query status and diagnostics information;
Query transponder serial numbers
Power supply
24 VDC
Display elements
3-color LED
(operating voltage, presence, error)
Plug connector
M12 (8-pin)
Housing
●
Dimensions (in mm)
●
Color
●
Material
●
160 x 80 x 41 (without M12 device connector)
●
Anthracite
●
Plastic PA 12
Mounting
4 x M5 screws
Ambient temperature
●
Operation
●
Transport and storage
●
-25
℃
... +70
℃
●
-40
℃
... +85
℃
Degree of protection to EN 60529
Shock to EN 60721-3-7 Class 7 M2
Vibration to EN 60721-3-7 Class 7 M2
IP67
50 g
20 g
Weight
approx. 550 g
MTBF (Mean Time Between Failures)
1 x 10
6
h
Approvals
Radio to R&TTE guidelines EN 300 330,
EN 301489, CE
Current consumption
typ. 140 mA
Max. power consumption (DC input)
3.5 W