Acknowledgement:
Command Error code
BCC
0x01
All parameters must always be transferred together. If the reader configuration is not saved on the host, it is recommended
to first read out the parameters saved to the reader.
"Read status" telegram
The status that can be read out from the reader includes version information alongside the parameters.
Either the retentive or the non-retentive parameters can be read out; the version information is always the same.
After the acknowledgement is sent with the requested data, the reader switches automatically back to scan mode.
"Read parameters" telegram:
Command Status
Quantity
1st byte
2nd byte
...
20th byte
21st byte
BCC
0x02
0x00
21
0x00
0x00
...
0x00
0x00
"Read parameters retentively" telegram:
Command Status
Quantity
1st byte
2nd byte
...
20th byte
21st byte
BCC
0x02
0x01
21
0x00
0x00
...
0x00
0x00
Acknowledgement:
Comm
and
Error
code
Quantit
y
1st
byte
2nd
byte
...
20th
byte
21st
byte
22nd
byte
23rd
byte
24th
byte
25th
byte
BCC
0x02
25
Para
Para
...
Para
Para
Para
Para
Para
Para
"Activate test mode" telegram
A test mode can be set to support the commissioning of a reader. The test mode is immediately active in the reader after the
acknowledgement is sent and can be deactivated only by switching off the reader or by sending a new parameter set.
In test mode, the reader scans constantly for a tag. Successful scans (a tag has responded) and unsuccessful scans
(incorrect or no response from a tag) are counted. The number of successful scans is permanently transferred to the host by
the reader. The reference point is 20 scans.
The transferred value provides information about how well a tag is positioned in, or passes through, the reader's HF field.
"Activate test mode" telegram:
Command Status
Quantity
1st byte
2nd byte
...
20th byte
21st byte
BCC
0x03
0x01
21
0xxx
0xxx
...
0xxx
0xxx
Acknowledge
Command Error code
BCC
0x03