![Siemens Simatic RF382R Scanmode Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/siemens/simatic-rf382r-scanmode/simatic-rf382r-scanmode_compact-operating-instructions_374418013.webp)
SIMATIC RF382R Scanmode
J31069-D0214-U001-A4-7618, 10/2013
13
Error code
An error code is saved in the second byte of the acknowledgement of the reader. If the telegram is processed without error,
the error code "00" is stored.
An error code other than zero means that the parameters have not been accepted. The following error codes are defined:
Error code
Meaning
0x01
Command (in the first byte of the telegram) is unknown
0x02
Status (in the second byte of the telegram) is unknown
0x03
A parameter setting is incorrect
0x04
BCC (in the last byte of the telegram) is incorrect
0x05
Data cannot be stored retentively
(FEPROM on module is not recognized)
0x06
Data cannot be stored retentively
(FEPROM sector cannot be deleted)
0x07
Data cannot be stored retentively
(FEPROM sector cannot be programmed)
9.3
Parameter assignment
Parameters for the RF382R Scanmode reader can be set simply using the RF MANAGER Basic. You will find the required
software components on the DVD "RFID Systems, Software & Documentation" or on the Internet using the following links:
SIMATIC RF MANAGER Basic V3.0 (
http://support.automation.siemens.com/WW/view/en/64700331
SIMATIC RF MANAGER Basic V3.0 Service Pack 1 (
http://support.automation.siemens.com/WW/view/en/78473837
Reader parameter assignment
Proceed as follows to set parameters for the RF382R Scanmode reader:
1.
Start the RF MANAGER Basic.
2.
In the area "Create an empty project", select the country in which the reader will be operated from the drop-down list.
3.
In the "Reader type" drop-down list, select the appropriate reader.