ISO 15693 host commands
9.2 Supported ISO 15693 host command for ISO 15693 transponders
RF290R
Configuration Manual, 09/2014, C79000-G8976-C377-01
85
Command code Function
Mode
Comment
0x2B
Get System
Information
-
-
-
-
-
0x2C
Get Multiple
Block Security
Status
✓
✓
✓
✓
-
1) The WR-OPTION is set automatically by the reader if the WR-OPTION parameter in the "CFG4 transponder parameters"
is set to "00: specified automatically". With one request, up to two blocks can be written with data.
9.2.7
Infineon (My-d-Light)
Chip ID: A1h = 10100001b (bit 47 - 40 of UID)
Table 9- 13 Memory arrangement 18 × 4 bytes = 576 bits
Number of blocks
18 (user range: 0 ... 12)
Block size
4 bytes
Command code Function
Mode
Comment
-
-
not addressed addresses
Selection
-
0x01
Inventory
✓
-
-
-
-
0x02
Stay Quiet
✓
-
✓
-
-
0x22
Lock Multiple
Blocks
✓
✓
✓
✓
WR-OPTION = 0
1)
0x23
Read Multiple
Blocks
✓
✓
2)
✓
✓
DB-SIZE = 4
0x24
Write Multiple
Blocks
✓
✓
✓
✓
DB-SIZE = 4
WR-OPTION = 0
1)
0x25
Select
✓
-
✓
-
-
0x26
Reset to Ready
✓
✓
✓
✓
-
0x27
Write AFI
✓
✓
✓
✓
WR-OPTION = 0
1)
0x28
Lock AFI
✓
✓
✓
✓
WR-OPTION = 0
1)
0x29
Write DSFID
-
-
-
-
-
0x2A
Lock DSFID
-
-
-
-
-
0x2B
Get System
Information
-
-
-
-
-
0x2C
Get Multiple
Block Security
Status
-
-
-
-
-
1) The WR-OPTION is set automatically by the reader if the WR-OPTION parameter in the "CFG4 transponder parameters"
is set to "00: specified automatically". With one request, up to two blocks can be written with data.
2) Reading a block in non-addressed mode is only possible if the "Read mode" parameter in the "CFG4 transponder pa-
rameters" is set to "b01: read once".