Configuration parameters (CFG)
5.10 CFG12: Read mode - filter
RF290R
34
Configuration Manual, 09/2014, C79000-G8976-C377-01
1)
You will find further information on valid addresses and data block sizes in the section
"Supported ISO 15693 host command for ISO 15693 transponders (Page 79)".
5.10
CFG12: Read mode - filter
Byte
0
1
2
3
4
5
6
Content
VALID-TIME
TR-ID
0x00
Default
0x0037
5,5 s
0x01000001
-
Byte
7
8
9
10
11
12
13
Content
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
-
-
-
-
-
-
-
Name
Description
VALID-
TIME
The period during which a transponder cannot be read a second time.
0...65535 x 100 ms = 0 ms ... 6553.5 s
Note:
A change to VALID-TIME only takes effect after configuration block CFG12 has been written to the EEPROM
and the CPU has been reset.
TR-ID
TR-ID specifies the parameters for the transponder identification. If several transponders have the same con-
tent in the addressed data block, only one data set is generated.
This function is available only in "Buffered Read Mode".
Byte
2
3
4
5
Function
TR-ID-SOURCE
TR-ID-DB-ADR
TR-ID-DB-N
Function
Description
TR-ID-
SOURCE
Specifies the data source for the transponder identification.
•
b0 data block
•
b1 serial number
TR-ID-DB-
ADR
Specifies the address of the data block for the transponder identification. If the serial number is
selected as the data source in ID-SOURCE, ID-DB-ADR is ignored.
TR-ID-DB-N Specifies the number of data blocks to be read for the transponder identification. If the serial
number is selected as the data source in "TR-ID-SOURCE", "TR-ID-DB-N" is ignored.