Troubleshooting/FAQs
13.2 Problems when Using Modules of Third-party Manufacturers
SIMATIC Rack PC 847B
112
Operating Instructions, 06/2008, A5E02203168-01
13.2
Problems when Using Modules of Third-party Manufacturers
Problem
Possible cause
To correct or avoid error
Check your computer configuration:
•
Contact Technical Support if the computer configuration
corresponds with the delivery state.
•
If the computer configuration has changed, restore the
original factory settings. Remove all third-party modules,
then restart the computer. If the error no longer occurs, the
third-party module was the cause of the fault. Replace the
thrid-party module with a Siemens module or contact the
module supplier.
•
Force a "Reset Configuration" using the BIOS Setup.
•
Redundant I/O addresses
•
Redundant hardware interrupts
and/or DMA channels
•
Fluctuation of signal frequencies
or levels
•
Connector pin assignments
deviate
•
No "Reset Configuration" in
BIOS SETUP
Contact Technical Support if the PC still crashes.
The PC crashes
during startup
•
Insufficient output of an external
power supply (UPS, for
example)
•
Use a higher capacity power supply
PC does not
restart or turns off
immediately
•
A voltage > 0.5 V is fed into the
PC due to connected or installed
third-party components
Check with the supplier of the component
•
whether this can be operated without an external power
supply,
•
whether the settings for the component can be changed so
that only the PC power supply is used or only the external
power supply.