WARNING
EXPLOSION HAZARD
You may only connect or disconnect cables carrying electricity when the power supply is
switched off or when the device is in an area without inflammable gas concentrations.
Safety notices for use according to ATEX and IECEx
If you use the device under ATEX or IECEx conditions you must also keep to the following
safety notices in addition to the general safety notices for protection against explosion:
WARNING
Take measures to prevent transient voltage surges of more than 40% of the rated voltage.
This is the case if you only operate devices with SELV (safety extra-low voltage).
WARNING
Provisions shall be made to prevent the rated voltage from being exceeded by transient
disturbances of more than 119 V.
Further notes
WARNING
Safety notice for connecting with a LAN ID (Local Area Network)
A LAN or LAN segment with all the interconnected devices should be contained completely in
a single low voltage power distribution in a building. The LAN is designed either for
“Environment A” according to IEEE802.3 or "Environment 0" according to IEC TR 62102.
Do not connect any electrical connectors directly to the telephone network (telephone network
voltage) or a WAN (Wide Area Network).
Connecting up
6.1 Safety when connecting up
SCALANCE XB-200
34
Operating Instructions, 03/2020, C79000-G8976-C359-09
Содержание SIMATIC NET SCALANCE XB-200 Series
Страница 10: ...Safety notices SCALANCE XB 200 10 Operating Instructions 03 2020 C79000 G8976 C359 09 ...
Страница 16: ...Recommendations on network security SCALANCE XB 200 16 Operating Instructions 03 2020 C79000 G8976 C359 09 ...
Страница 32: ...Installation 5 2 Mounting on DIN rails SCALANCE XB 200 32 Operating Instructions 03 2020 C79000 G8976 C359 09 ...
Страница 44: ...Connecting up 6 6 Functional ground SCALANCE XB 200 44 Operating Instructions 03 2020 C79000 G8976 C359 09 ...