There are two TP port groups:
Group 1: P1
Group2: P2 to P5
Between ports of different port groups, an insulation voltage of 1.5 kV is adhered to
(corresponds to IEEE802.3, Chapter 33.4.1.1, Environment B), e.g. between P1 and P2.
The requirements for Environment A are met between ports of the same group, e.g. between
P2 and P5.
Devices without port groups
The following devices do not have port groups:
● SCALANCE X005
6GK5 005-0BA10-1AA3
● SCALANCE X005EEC
6GK5 005-0BA10-1CA3
The requirements for Environment A are met between all ports.
4.4
LEDs
Power LED "L" (green LED)
The power LED shows the status of the power supply.
LED color
LED status
Meaning
Green
Lit
Power supply is connected.
-
Off
Power supply is not connected or <14 V.
Port LEDs "P" (green/yellow LEDs)
The port LEDs indicate the status of the ports.
LED color
LED status
Meaning
Green
Lit
TP link exists, no data reception at port
Yellow
Lit
TP link exists, data reception at port
Yellow
Flashing
Test phase during power on
Description of the device
4.4 LEDs
SCALANCE X-000
Operating Instructions, 12/2018, C79000-G8976-C344-03
19
Содержание SIMATIC NET SCALANCE X-000 Series
Страница 4: ...Table of contents SCALANCE X 000 4 Operating Instructions 12 2018 C79000 G8976 C344 03 ...
Страница 10: ...Safety notices SCALANCE X 000 10 Operating Instructions 12 2018 C79000 G8976 C344 03 ...
Страница 12: ...Network topologies SCALANCE X 000 12 Operating Instructions 12 2018 C79000 G8976 C344 03 ...
Страница 20: ...Description of the device 4 4 LEDs SCALANCE X 000 20 Operating Instructions 12 2018 C79000 G8976 C344 03 ...
Страница 32: ...Connecting up 6 5 IE FC RJ 45 Plug 180 SCALANCE X 000 32 Operating Instructions 12 2018 C79000 G8976 C344 03 ...
Страница 34: ...Maintenance and troubleshooting SCALANCE X 000 34 Operating Instructions 12 2018 C79000 G8976 C344 03 ...
Страница 40: ...Technical specifications SCALANCE X 000 40 Operating Instructions 12 2018 C79000 G8976 C344 03 ...