Mounting
4.5 Installation with mounting plate
SCALANCE W786C
34
Operating Instructions, 07/2019, A5E03692138-12
To screw the cover plate for the cable feedthrough to the mounting plate, follow the steps
below:
1.
Fit the cover plate on the mounting plate from below until the two lugs (position A in the
figure above) engage the lower edge of the mounting plate.
2.
Secure the cover plate to the mounting plate with two M4 screws. The screws are
supplied with the assembly kit.
4.5.3
Fitting the mounting plate to an S7-300 standard rail
Procedure
Figure 4-9
Side view of a mounting plate on an S7-300 standard rail
Follow the steps below to fit the mounting plate to an S7-300 standard rail:
1.
Place the mounting plate with the two protruding catches on the top edge of the S7-300
standard rail (position A in the figure above).
2.
At the bottom, the mounting plate has two lugs with holes. Screw the lugs to the S7-300
standard rail (position B in the figure above). The required screws are supplied with the
mounting plate.