Technical specifications
5.1 SCALANCE W786-2HPW technical specifications
SCALANCE W786-2HPW
42
Operating Instructions (Compact), 06/2007, A5E01186485
Construction
Dimensions
(W x H x D)
251 mm x 251 mm x 72 mm
Without power supply
adapter
2241 g
With power supply
adapter 12 V DC
2428 g
Weight
With power supply
adapter
110 - 230 V AC
2433 g
Permitted ambient conditions
Operating temperature
-40°C ... 70°C
Devices with fiber optic cable -25°C ... 70°C
Transport/storage temperature
-40°C to 85°C
Degree of protection
Tested to IP65
MTBF information (mean time between failure)
SCALANCE W786