Configuring with Web Based Management
5.9 "Security" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
276
Configuration Manual, 03/2015, C79000-G8976-C267-08
Description
Table 1 has the following columns:
●
Column 1
Shows that the settings are valid for all ports of table 2.
●
within own VAP / with other VAPs / with Ethernet
In the drop-down list, select the setting for all ports. If "No Change" is selected, the entry
in table 2 remains unchanged.
●
Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
●
Radio
Shows the available WLAN interfaces.
●
Port
Shows the VAP interface.
●
Within own VAP
–
Enabled
Clients logged on to the same VAP interface of an access point can communicate with
each other.
–
Disabled
Option is disabled.
●
With other VAPs
–
Enabled
Clients logged on to different VAP interfaces of an access point can communicate with
each other.
–
Disabled
Option is disabled.
Note
For an access point, "With other VAP" must be enabled on all WLAN interfaces or on
all VAPs to allow communication between clients logged on at different VAP interfaces
of the access point.
●
With ethernet
–
Enabled
Clients can communicate via the Ethernet interface of the access point.
–
Disabled