Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08
171
Description
The page contains the following boxes:
●
"Pool ID" drop-down list
Select the required IPv4 address band.
●
"Option Code" input box
Enter the number of the required DHCP option. A maximum of 20 DHCP options are
possible.
The various DHCP options are defined in RFC 2132. The DHCP options 1, 3, 6, 66 and
67 are created automatically when the IPv4 address band is created. With the exception
of option 1, the options can be deleted.
With the DHCP option 3, the internal IPv4 address of the device is automatically set as a
DHCP parameter.
Note
DHCP options not supported
The DHCP options 50 - 60 and 255 are not supported.
The table has the following columns:
●
Select
Select the check box in the row to be deleted.
●
Pool ID
Shows the number of the IPv4 address band.
●
Option Code
Shows the number of the DHCP option.
●
Use Interface IP
Specify whether or not the internal IPv4 address of the device will be used.
●
Value
Enter the DHCP parameter that is transferred to the DHCP client. The content depends
on the DHCP option.
–
DHCP option 67 (boot file name)
Enter the name of the boot file in the string format.
–
DHCP options 3 (router), 6 (DNS) and 66 (TFTP server):
Enter the DHCP parameter as an IPv4 address, e.g. 192.168.100.2. With the
exception of DHCP option 3, you can specify several IPv4 addresses separated by
commas.
–
All other DHCP options
Enter the DHCP parameter in hexadecimal, e.g. the IPv4 address 192.168.100.2
corresponds to "C0A86402".