Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
198
Configuration Manual, 03/2015, C79000-G8976-C267-08
5.5.15
Fault Monitoring
5.5.15.1
Power Supply
Settings for monitoring the power supply
Configure whether or not the power supply should be monitored by the messaging system.
Depending on the hardware variant there are one or two power connectors (Line 1 / Line 2)
and a PoE power supply. With a redundant power supply, configure the monitoring
separately for each individual feed-in line.
A fault is then signaled by the message system when there is no power on a monitored line
(Line 1, Line 2 or PoE) or when the applied voltage is too low.
Note
You will find the permitted operating voltage limits in the operating instructions of the device.
A fault causes the signaling contact to trigger and the fault LED on the device to light up and,
depending on the configuration, can trigger a trap, an e-mail, or an entry in the event log
table.
Note
This WBM page is not available on the SCALANCE W786-2 SFP.
Procedure
1.
Click the check box in front of the line name you want to monitor to enable or disable the
monitoring function.
2.
Click the "Set Values" button.