Configuring with Web Based Management
4.3 "Information" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
87
Description
•
Severity Filters
You can filter the entries in the table according to severity. To display all the entries,
enable or disable all parameters.
Note
For each severity, a maximum of 400 entries in the table are possible. If the maximum
number of entries is reached for a severity, the oldest entries of this severity are
overwritten in the table. The table remains permanently in the memory.
–
Critical
Critical
When this parameter is enabled, all entries of the category "Critical" are displayed.
–
Warning
warning
When this parameter is enabled, all entries of the category "Warning" are
displayed.
–
Info
Informative
When this parameter is enabled, all entries of the category "Info" are displayed.
The table has the following columns:
•
Restart
Counts the number of restarts since you last reset to factory settings and shows the
device restart after which the corresponding event occurred.
•
System Up Time
Shows the time the device has been running since the last restart when the described
event occurred.
•
System Time
Shows the date and time when the described event occurred. If no system time is set,
the box displays "Date/time not set".
•
Severity
Sorts the entry into the categories above.
•
Log Message
Displays a brief description of the event that has occurred.
Содержание SIMATIC NET SCALANCE SC-600