Technical basics
3.1 IP address
SCALANCE SC-600 Web Based Management (WBM)
36
Configuration Manual, 10/2021, C79000-G8976-C475-03
3.1.3
Initial assignment of an IP address
Configuration options
An initial IP address for the device cannot be assigned using Web Based Management
(WBM) because this configuration tool can only be used if an IP address already exists.
The following options are available to assign an IP address to an unconfigured device:
•
DHCP
(default)
Note
When the product ships and following "Restore Factory Defaults and Restart", DHCP
is enabled. If a DHCP server is available in the local area network, and this responds
to the DHCP request of a device, the IP address, subnet mask and gateway are
assigned automatically when the device first starts up.
Note
DHCP on VLAN 2 must not be used for initial configuration.
You will find the VLAN assignment set on the device in the factory in the section
VLAN (Page 40).
•
SINEC PNI
–
To be able to assign an IP address to the device with SINEC PNI, it must be
possible to reach the device via Ethernet.
–
You can find SINEC PNI on the Internet pages of Siemens Industry Online Support:
Link: (
https://support.industry.siemens.com/cs/ww/en/ps/26672/dl
–
For additional information about assigning the IP address with SINEC PNI, refer to
the online help or the "SINEC PNI network management" operating instructions.
•
CLI
via the serial interface
For further information on assigning the IP address using the CLI, refer to the
configuration manual "SCALANCE SC-600 Command Line Interface (CLI)".
3.1.4
Address assignment with DHCP
Properties of DHCP
DHCP (Dynamic Host Configuration Protocol) is a method for automatic assignment of
IP addresses. It has the following characteristics:
•
DHCP can be used both when starting up a device and during ongoing operation.
•
The assigned IP address remains valid only for a limited time known as the lease
time. When half the period of validity has elapsed. the DHCP client can extend the
period of the assigned IPv4 address. When the entire time has elapsed, the DHCP
client needs to request a new IPv4 address.