Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
189
5.
In "SNTP Server Port", enter the port via which the SNTP server is available. The port
can only be modified if the IP address of the SNTP server is entered.
6.
In "Poll Interval[s]", enter the time in seconds after which a new time query is sent to
the time server.
7.
Click the "Set Values" button.
4.4.10.5
NTP Client
Automatic time-of-day setting with NTP
If time synchronization is to take place via NTP, define the time server that is used to
synchronize the time.
Note
To avoid time jumps, make sure that there is only one time server in the network.
Requirement
To receive the NTP frames, enable the entry "System Time" under "Security > Firewall >
Pre-defined IPv4 rules".
Содержание SIMATIC NET SCALANCE SC-600
Страница 68: ......