background image

Edition

07/2021

Installation Manual

SIMATIC NET

Rugged Ethernet Switches

RUGGEDCOM RSG2488F

https://www.siemens.com

Содержание SIMATIC NET RUGGEDCOM RSG2488F

Страница 1: ...Edition 07 2021 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RSG2488F https www siemens com ...

Страница 2: ... Rugged Ethernet Switches RUGGEDCOM RSG2488F Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Modules 4 Technical Specifications 5 Certification 6 07 2021 C79000 G8976 1351 07 ...

Страница 3: ...ied personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufact...

Страница 4: ... 5 1 6 Tamper Evident Security Seals 5 2 Installing the Device 7 2 1 General Procedure 8 2 2 Unpacking the Device 8 2 3 Mounting the Device 8 2 3 1 Mounting the Device to a Rack 9 2 3 2 Mounting the Device on a DIN Rail 9 2 3 3 Mounting the Device to a Panel 11 2 4 Connecting the Failsafe Alarm Relay 12 2 5 Connecting Power 13 2 5 1 Connecting High AC DC Power 14 2 5 2 Connecting Low DC Power 15 2...

Страница 5: ... Specifications 31 5 3 Supported Networking Standards 32 5 4 Operating Environment 32 5 5 Mechanical Specifications 32 5 6 Dimension Drawings 32 6 Certification 37 6 1 Approvals 37 6 1 1 TÜV SÜD 37 6 1 2 European Union EU 37 6 1 3 FCC 38 6 1 4 ISED 38 6 1 5 ISO 38 6 1 6 RoHS 39 6 1 7 Other Approvals 39 6 2 EMC and Environmental Type Tests 39 iv RUGGEDCOM RSG2488F Installation Manual 07 2021 C79000...

Страница 6: ...SFP Transceivers Catalog https support industry siemens com cs ww en view 109482309 Time Synchronization Capabilities of RUGGEDCOM Devices https support industry siemens com cs ww en view 109780448 Accessing Documentation The latest user documentation for RUGGEDCOM RSG2488F is available online at https support industry siemens com To request or inquire about a user document contact Siemens Custome...

Страница 7: ...rking Ethernet switches and routers to on site customized courses tailored to the customer s needs experience and application Siemens Educational Services team thrives on providing our customers with the essential practical skills to make sure users have the right knowledge and expertise to understand the various technologies associated with critical communications network infrastructure technolog...

Страница 8: ...ing SR Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 856 1995 E Mail info ruggedcom siemens com Web http...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RSG2488F Installation Manual 07 2021 C79000 G8976 1351 07 ...

Страница 10: ...e Highlights Extreme Flexibility Support for up to a total of 28 non blocking ports six 4 port modules and two 2 port modules Mixture of fiber optic or copper Gigabit ports with up to 28 Gig Ethernet ports All aluminum construction Compact 1U Form Factor Space saving design Vertical Loading Modular Design Allows for simple cost effective in field servicing and upgrading Dual Redundant Smart Power ...

Страница 11: ...488F Power Status LEDs Indicates the status of the power modules LED Description I The power module is receiving power O The power module is supplying power RS 232 Console Port The serial console port is for interfacing directly with the device and accessing initial management functions For information about connecting to the device via the serial console port refer to Connecting to the Device Pag...

Страница 12: ...block For more information refer to Connecting Power Page 13 Power Supply Specifications Page 31 Chassis Ground Terminal Protects the device from power surges and accumulated static electricity For information about grounding the device refer to Grounding the Device Page 16 1 3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RSG2488F Tools Mater...

Страница 13: ...l event communications errors or interruptions may occur but recovery is automatic Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise i e greater than 2500 V during line to ground fault conditions 1 5 2 Gigabit Ethernet 1000Base TX Cabling Recommendations The IEEE 802 3ab Gigabi...

Страница 14: ... screened cabling can be used when required Care should be taken to avoid the creation of ground loops with shielded cabling 1 5 3 Supported Fiber Optic Cables The following fiber optic cable types are supported under the stated conditions Distance m Cable Type Wavelength nm Modal Bandwidth MHz km 100Base FX 1000Base SX 10GBase SR 850 200 275 33 OM1 62 5 125 1300 500 2000 850 500 550 82 OM2 50 125...

Страница 15: ... with The seal is cut or torn A pattern is left on the device when the top layer of the seal is removed Residue left by the seal is visible on the device under ultra violet light For information about the placement of security seals refer to the RUGGEDCOM RSG2488F FIPS 140 2 Non Proprietary Security Policy https support industry siemens com cs ww en view 109757984 6 RUGGEDCOM RSG2488F Installation...

Страница 16: ...e of the device may be hot during operation or as a result of the ambient air temperature Wear appropriate personal protective equipment and use caution when working with or around the device NOTICE This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly approved by Siemens AG could...

Страница 17: ...installation and regulatory requirements 3 Mount the device 4 Connect the failsafe alarm relay 5 Connect power to the device and ground the device to safety Earth 6 Connect the device to the network 7 Configure the device 2 2 Unpacking the Device When unpacking the device do the following 1 Inspect the package for damage before opening it 2 Visually inspect each item in the package for any physica...

Страница 18: ...following 1 Make sure the front and rear rack mount adapters are installed on the both sides of the chassis Note The chassis features multiple mounting holes allowing the rack mount adapters to be installed up to 25 mm 1 in from the face of the device 3 3 2 1 1 Rear 2 Front 3 Rack Mount Adapter Figure 2 1 Rack Mount Adapters 2 Insert the device into the rack To make the modules and ports accessibl...

Страница 19: ...s onto the DIN rail 1 3 1 2 2 3 3 3 1 DIN Rail 2 DIN Rail Adapter 3 Screw Figure 2 2 Mounting the Device to a DIN Rail 2 Rest the device against the bottom of the DIN rail 3 Secure the device to the DIN rail with at least one screw supplied Apply screws to the adapters on either side of the device 10 RUGGEDCOM RSG2488F Installation Manual 07 2021 C79000 G8976 1351 07 ...

Страница 20: ...Screw Figure 2 3 Removing the Device from a DIN Rail 2 Swing the bottom of the device away from the DIN rail 3 Lift the device off the DIN rail 2 3 3 Mounting the Device to a Panel For panel installations the RUGGEDCOM RSG2488F can be ordered with panel DIN rail adapters pre installed on each side of the chassis The adapters allow the device to be attached to a panel using screws RUGGEDCOM RSG2488...

Страница 21: ...nditions The NO Normally Open contact is closed when the unit is powered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM RSG2488F One common application for this relay is to signal an alarm if a power fa...

Страница 22: ...ock or vibration DANGER Electrocution hazard risk of serious personal injury or death The device may have two power supplies equipped which may be connected to separate power sources Make sure all power sources are off before servicing the power supply terminals NOTICE Electrical hazard risk of damage to equipment Do not connect wiring to unused power supply input terminals For instance if a Low D...

Страница 23: ...nect device must be installed near the device and be easily accessible Equipment must be installed according to applicable local wiring codes and standards 2 5 1 Connecting High AC DC Power To connect a high AC DC power supply to the device do the following DANGER Electrocution hazard risk of death serious personal injury and or damage to the device Make sure the supplied cover is always installed...

Страница 24: ...Connect the negative wire from the power source to the neutral negative N terminal on the terminal block 3 Connect the ground terminal on the power source to the ground terminal on the device For more information refer to Grounding the Device Page 16 2 5 2 Connecting Low DC Power To connect a low DC power supply to the device do the following Note The screw type terminal block is installed using P...

Страница 25: ...Chassis Ground Figure 2 7 DC Terminal Block Wiring 2 Connect the negative wire from the power source to the negative terminal on the terminal block 3 Connect the ground terminal on the power source to the ground terminal on the device For more information refer to Grounding the Device Page 16 2 5 3 Grounding the Device The RUGGEDCOM RSG2488F chassis ground terminal uses an M3 screw It is recommend...

Страница 26: ...sis Ground Connection 2 5 4 Wiring Examples The following illustrate how to connect power to single and dual power supplies Figure 2 9 Single High AC DC Power Supply Figure 2 10 Single Low DC Power Supply RUGGEDCOM RSG2488F Installation Manual 07 2021 C79000 G8976 1351 07 17 ...

Страница 27: ...Installing the Device 2 5 4 Wiring Examples Figure 2 11 Dual High AC DC Power Supply Figure 2 12 Dual Low DC Power Supply 18 RUGGEDCOM RSG2488F Installation Manual 07 2021 C79000 G8976 1351 07 ...

Страница 28: ...Installing the Device 2 5 4 Wiring Examples Figure 2 13 High AC DC Power Supply and Low DC Power Supply RUGGEDCOM RSG2488F Installation Manual 07 2021 C79000 G8976 1351 07 19 ...

Страница 29: ...Installing the Device 2 5 4 Wiring Examples 20 RUGGEDCOM RSG2488F Installation Manual 07 2021 C79000 G8976 1351 07 ...

Страница 30: ...cess the boot time control and RUGGEDCOM RSG2488F interfaces The serial console port provides access to RUGGEDCOM RSG2488F s console interface while the management port provides access to RUGGEDCOM RSG2488F s console and Web interfaces The serial console port implements RS 232 DCE Data Communication Equipment on a DB9 connector The following is the pin out for the port 5 9 6 1 Figure 3 1 Serial DB...

Страница 31: ...nd access the RUGGEDCOM RSG2488F console and Web interfaces via the device s IP address The factory default IP address for the RUGGEDCOM RSG2488F is https 192 168 0 1 If connecting to the management port use the address https 10 0 0 1 For more information about available ports refer to Modules Page 25 Note Single mode fiber ports only support Ultra Physical Contact UPC cable connectors 3 2 Configu...

Страница 32: ...y Do not expose the microSD card to large magnetic or static electric fields Do not bend or drop the microSD card NOTICE Security hazard risk of unauthorized access and or exploitation Make sure to remove the microSD card before decommissioning the device or sending the device to a third party To insert or remove a microSD card do the following 1 Power down the device 2 Unscrew the retention screw...

Страница 33: ...Device Management 3 3 Inserting Removing the MicroSD Card 24 RUGGEDCOM RSG2488F Installation Manual 07 2021 C79000 G8976 1351 07 ...

Страница 34: ...lled in any one of the available slots in the device chassis Use the RUGGEDCOM RSG2488F software to determine which ports are equipped on the device For more information refer to the RUGGEDCOM ROS F Configuration Manual for the device 3 4 1 2 5 7 6 8 9 10 1 Power Module Slot PS1 2 Power Module Slot PS2 3 Line Module Slot Slot 1 4 Line Module Slot Slot 2 5 Line Module Slot Slot 3 6 Line Module Slot...

Страница 35: ...e information refer to the RUGGEDCOM ROS F Configuration Manual for the RUGGEDCOM RSG2488F Once a line module is removed all the features associated with the module are hidden or disabled in RUGGEDCOM RSG2488F NOTICE Only one Precision Time Protocol PTP line module is supported per chassis NOTICE Contamination hazard risk of equipment damage Prevent the ingress of water dirts and other debris that...

Страница 36: ...al If necessary install the device in the rack 7 Connect power to the device Installing a Module To install a line module do the following 1 Make sure power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate 2 Optional If the device is installed in a rack remove it from the rack 3 Remove the current module from the slot RUGGEDCOM RSG2488F I...

Страница 37: ...ional If necessary install the device in the rack 7 Connect power to the device 4 3 Installing Removing Power Modules The RUGGEDCOM RSG2488F supports dual redundant power supply modules 1 2 1 Power Supply Module PS1 2 Power Supply Module PS2 Figure 4 4 Power Supply Modules NOTICE Contamination hazard risk of equipment damage 28 RUGGEDCOM RSG2488F Installation Manual 07 2021 C79000 G8976 1351 07 ...

Страница 38: ...oving a Power Module To remove a power module do the following 1 Loosen the screws that secure the module to the chassis until the module can be removed 2 3 1 1 Screws 2 Power Supply 3 Chassis Figure 4 5 Removing a Power Supply 2 Slide the module out of the chassis 3 Install a new or blank module to prevent the ingress of dust and dirt Installing a Power Module To install a power module do the fol...

Страница 39: ... Hand tighten the screws to secure the power module to the chassis 4 Turn on power to the device and confirm the module is receiving and supplying power This is indicated by the LEDs on the module LED State Description O Green The module is supplying power I Green The module is receiving power 30 RUGGEDCOM RSG2488F Installation Manual 07 2021 C79000 G8976 1351 07 ...

Страница 40: ...ating Maximum Power Consumption 24 VDC Single 13 VDC 36 VDC 10 A 62 W 48 VDC Single 38 VDC 72 VDC 5 A 59 W 98 VDC 300 VDC High Voltage AC DC 88 VAC a 264 VAC a 3 15 A 66 W a Rated at frequency range 47Hz 63Hz 5 2 Failsafe Alarm Relay Specifications NOTICE The alarm switching voltage must be greater than the Safety Extra Low Voltage SELV to meet safety requirements Parameter Value Resistive Load Ma...

Страница 41: ...es Yes Yes Full duplex operation 5 4 Operating Environment Ambient Operating Temperature ab 40 to 85 C 40 to 185 F Ambient Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity c 5 to 95 Maximum Altitude 2000 m 6562 ft a Measured from a 30 cm 11 8 in radius surrounding the center of the enclosure b Operating temperature may vary based on the limitations of installed SFPs Refer to th...

Страница 42: ...Technical Specifications 5 6 Dimension Drawings 376 0 442 4 44 0 Figure 5 1 Overall Dimensions RUGGEDCOM RSG2488F Installation Manual 07 2021 C79000 G8976 1351 07 33 ...

Страница 43: ...pecifications 5 6 Dimension Drawings 24 4 369 8 350 2 43 9 31 8 4 7 6 4 483 5 465 2 51 1 248 4 299 5 21 1 44 Figure 5 2 Rack Mount Dimensions 34 RUGGEDCOM RSG2488F Installation Manual 07 2021 C79000 G8976 1351 07 ...

Страница 44: ...4 5 277 4 98 6 25 4 51 6 7 6 148 3 227 7 480 5 160 0 1 1 DIN Rail Centerline Figure 5 3 Panel and Din Rail Mount Dimensions 110 0 91 4 21 8 104 1 Figure 5 4 4 Port Line Module Dimensions RUGGEDCOM RSG2488F Installation Manual 07 2021 C79000 G8976 1351 07 35 ...

Страница 45: ...fications 5 6 Dimension Drawings 49 8 21 8 91 4 95 0 Figure 5 5 2 Port Line Module Dimensions 43 9 129 8 196 6 Figure 5 6 Power Module Dimensions 36 RUGGEDCOM RSG2488F Installation Manual 07 2021 C79000 G8976 1351 07 ...

Страница 46: ...ds CSA EN IEC UL 62368 1 Information Technology Equipment Safety Part 1 General Requirements 6 1 2 European Union EU This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives EN 62368 1 Information Technology Equipment Safety Part 1 General Requirements EN 61000 6 2 Electromagnetic Compatibility EMC Part 6 2 Generic Sta...

Страница 47: ... energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense NOTICE Changes or modifications not expressly approved by the party responsible for compl...

Страница 48: ...ower Substations IEC 61850 3 General Requirements IEC 61000 6 2 Electromagnetic Compatibility EMC Part 6 2 Generic Standards Immunity for Industrial Environments 6 2 EMC and Environmental Type Tests The RUGGEDCOM RSG2488F has passed the following EMC and environmental tests EMC Type Test for IEC 61850 3 Note In the case of an all fiber port configuration this product meets all Class 2 requirements...

Страница 49: ...s 1000 A m for 3 s 5 IEC 61000 4 10 Damped Oscillating Magnetic Field Enclosure Ports 100 A m for 1 s 100 kHz and 1 MHz 5 IEC 61000 4 11 Voltage Dips and Interrupts AC Power Ports 30 for 1 period 60 for 50 periods 100 for 5 periods 100 for 50 periods Signal Ports DC Power Ports IEC 61000 4 12 Damped Oscillatory AC Power Ports 2 5 kV Common 1 kV Differential Mode 1 MHz 3 Signal Ports DC Power Ports...

Страница 50: ...rts Class 1 allows for temporary communication loss while Class 2 requires error free and interrupted communications Description Test Levels Signal Ports 5 kV Failsafe Relay Output DC Power Ports HV Impulse AC Power Ports 5 kV Signal Ports 2 kV DC Power Ports 1 5 kVDC Dielectric Strength AC Power Ports 2 kV Signal Ports DC Power Ports AC Power Ports 4 kV 2 5 and 5 kHz Fast Transient Earth Ground P...

Страница 51: ...185 F IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 non condensing 55 C 131 F 6 Cycles IEC 60068 2 31 Free Fall Procedure 1 2 falls from a height of 250 mm 9 8 in IEC 60068 2 78 Humidity Damp Heat Steady State Test Cab 10 days 55 C 131 F and 93 Relative Humidity IEC 60255 21 1 Vibration Level 2 2 g 10 to 150 Hz Shock Level 2 30 g 11 mS IEC 60255 21 2 Bump Level 1 10 g 16 mS IEC 60529 Ingress...

Страница 52: ...ttps www siemens com ruggedcom Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...