Certification
6.2 EMC and Environmental Type Tests
Environmental Type Tests
Test
Description
Test Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40 °C (-40 °F), 16 Hours
IEC 60068-2-2
Dry Heat
Test Bd
85 °C (185 °F), 16 Hours
IEC 60068-2-14
Change of Temperature
Test Nb
5 Cycles, -40 to 85°
C (40 to 185° F)
IEC 60068-2-30
Humidity (Damp Heat, Cyclic)
Test Db
95% (non-condensing)
55 °C (131 °F), 6 Cycles
IEC 60068-2-31
Free Fall
Procedure 1, 2 falls from a
height of 250 mm (9.8 in)
IEC 60068-2-78
Humidity (Damp
Heat, Steady State)
Test Cab
10 days @ 55 °C (131 °F)
and 93% Relative Humidity
IEC 60255-21-1
Vibration
Level 2 (2 g @ 10 to 150 Hz)
Shock
Level 2 (30 g @ 11 mS)
IEC 60255-21-2
Bump
Level 1 (10 g @ 16 mS)
IEC 60529
Ingress Protection
IP3x
42
RUGGEDCOM RSG2488F
Installation Manual, 07/2021, C79000-G8976-1351-07