Technical Specifications
5
This section provides important technical specifications related to the device.
5.1
Power Supply Specifications
Note
Use the internal fuse rating to determine the size of the external circuit breaker/fuse.
Note
When determining cable lengths, make sure the minimum input voltage for the
power supply is provided at the power source.
Input Range
Power
Supply Type
Min
Max
Internal
Fuse Rating
Maximum Power
Consumption
24 VDC (Single)
13 VDC
36 VDC
10 A
62 W
48 VDC (Single)
38 VDC
72 VDC
5 A
59 W
98 VDC
300 VDC
High Voltage
AC/DC
88 VAC
3.15 A
66 W
Rated at frequency range 47Hz - 63Hz.
5.2
Failsafe Alarm Relay Specifications
NOTICE
The alarm switching voltage must be greater than the Safety Extra Low-Voltage
(SELV) to meet safety requirements.
Parameter
Value (Resistive Load)
Maximum Switching Voltage
250 VAC
30 VDC
Rated Switching Current
2 A @ 250 VAC
2 A @ 30 VDC
0.15 A @ 125 VDC
Maximum Switching Capacity
150 W
500 VA
RUGGEDCOM RSG2488F
Installation Manual, 07/2021, C79000-G8976-1351-07
31