background image

Certification

6.1.5 ISED

reasonable protection against harmful interference when the equipment is operated

in a commercial environment.
This device generates, uses and can radiate radio frequency energy and, if not

installed and used in accordance with the instruction manual, may cause harmful

interference to radio communications. Operation of this equipment in a residential

area is likely to cause harmful interference in which case users will be required to

correct the interference at their own expense.

IMPORTANT

Changes or modifications not expressly approved by the party responsible for

compliance could void the user's authority to operate this device.

6.1.5

ISED

This device is declared by Siemens AG to meet the requirements of the following

ISED (Innovation Science and Economic Development Canada) standard:
• CAN ICES-3 (A)/NMB-3 (A)

6.1.6

ISO

This device was designed and manufactured using a certified ISO (International

Organization for Standardization) quality program that adheres to the following

standard:

ISO 9001:2015

Quality management systems – Requirements

6.1.7

ACMA

This device meets the requirements of the following Australian Communications and

Media Authority (ACMA) standards under certificate ABN 98 004 347 880:
• Radiocommunications (Compliance Labelling – Devices) Notice 2014 made

under Section 182 of the Radiocommunications Act 1992

• Radiocommunications Labelling (Electromagnetic Compatibility) Notice 2008

made under Section 182 of the Radiocommunications Act 1992

• Radiocommunications (Compliance Labelling – Electromagnetic Radiation)

Notice 2003 made under Section 182 of the Radiocommunications Act 1992

• Telecommunications Labelling (Customer Equipment and Customer Cabling)

Notice 2001 made under Section 407 of the Telecommunication Act 1997

The device is marked with an RCM symbol to indicate compliance when sold in the

Australian region.

RUGGEDCOM RS940G

Installation Manual, 01/2021, C79000-G8976-1036-07

33

Содержание SIMATIC NET RUGGEDCOM RS940G

Страница 1: ...Edition 01 2021 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS940G https www siemens com ...

Страница 2: ...ed Ethernet Switches RUGGEDCOM RS940G Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 01 2021 C79000 G8976 1036 07 ...

Страница 3: ...ied personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufact...

Страница 4: ...ic Cables 5 2 Installing the Device 7 2 1 Unpacking the Device 7 2 2 Installing the Device in Hazardous Locations 8 2 3 Mounting the Device 9 2 3 1 Mounting the Device on a DIN Rail 9 2 3 2 Mounting the Device to a Panel 11 2 4 Connecting the Failsafe Alarm Relay 12 2 5 Connecting Power 13 2 5 1 Connecting High AC DC Power 14 2 5 2 Connecting Low DC Power 16 3 Device Management 19 3 1 Connecting t...

Страница 5: ...c Ethernet Port Specifications 26 5 6 Operating Environment 27 5 7 Mechanical Specifications 27 5 8 Dimension Drawings 27 6 Certification 31 6 1 Approvals 31 6 1 1 CSA 31 6 1 2 European Union EU 32 6 1 3 FDA CDRH 32 6 1 4 FCC 32 6 1 5 ISED 33 6 1 6 ISO 33 6 1 7 ACMA 33 6 1 8 RoHS 34 6 2 EMC and Environmental Type Tests 34 iv RUGGEDCOM RS940G Installation Manual 01 2021 C79000 G8976 1036 07 ...

Страница 6: ...ne at https support industry siemens com To request or inquire about a user document contact Siemens Customer Support Registered Trademarks RUGGEDCOM and ROS are trademarks of Siemens AG Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the owner Warranty Siemens warrants this product for a period of five 5 years fr...

Страница 7: ...critical communications network infrastructure technologies Siemens unique mix of IT Telecommunications expertise combined with domain knowledge in the utility transportation and industrial markets allows Siemens to provide training specific to the customer s application For more information about training services and course availability visit https www siemens com or contact a Siemens Sales repr...

Страница 8: ...emens customers and the support community Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 856 1995 E Mail ruggedcom info i ia siemens com Web https www siemens com RUGGEDCOM RS940G Installation Manual 01 2021 C79000 G8976 1036 07 vii ...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RS940G Installation Manual 01 2021 C79000 G8976 1036 07 ...

Страница 10: ...ng features such as Enhanced Rapid Spanning Tree eRSTP Port Rate Limiting and a full array of intelligent functionality for high network availability and manageability The versatility and wide selection of fiber optics allows the RUGGEDCOM RS940G to be used in a variety of applications The RUGGEDCOM RS940G provides two fiber optical Gigabit Ethernet ports for creating a fiber optical backbone with...

Страница 11: ...ocks for reliable maintenance free connections CSA UL 62368 1 safety approved to 85 C 185 F 1 2 Description The RUGGEDCOM RS940G features various ports controls and indicator LEDs on the front panel for connecting configuring and troubleshooting the device 3 4 8 9 2 1 1 6 7 5 1 Optional Ethernet Ports 2 Port Status LEDs 3 Ground Connection 4 Power Supply Terminal Block 5 Standard Copper Ethernet P...

Страница 12: ...other alarm condition occurs For more information refer to Connecting the Failsafe Alarm Relay Page 12 Failsafe Alarm Relay Specifications Page 25 1 3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RS940G Tools Materials Purpose AC or DC power cord 16 AWG For connecting power to the device CAT 5 Ethernet cables For connecting the device to the ...

Страница 13: ...round potential rise i e greater than 2500 V during line to ground fault conditions 1 5 2 Gigabit Ethernet 1000Base TX Cabling Recommendations The IEEE 802 3ab Gigabit Ethernet standard defines 1000 Mbit s Ethernet communications over distances of up to 100 m 328 ft using all 4 pairs in category 5 or higher balanced unshielded twisted pair cabling For wiring guidelines system designers and integra...

Страница 14: ... 90 angles when necessary to reduce inductive coupling Shielded screened cabling can be used when required Care should be taken to avoid the creation of ground loops with shielded cabling 1 5 3 Supported Fiber Optic Cables The following fiber optic cable types are supported under the stated conditions Distance m Cable Type Wavelength nm Modal Bandwidth MHz km 100Base FX 1000Base SX 10GBase SR 850 ...

Страница 15: ...Introduction 1 5 3 Supported Fiber Optic Cables 6 RUGGEDCOM RS940G Installation Manual 01 2021 C79000 G8976 1036 07 ...

Страница 16: ... This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly approved by Siemens AG could invalidate specifications test results and agency approvals and void the user s authority to operate the equipment IMPORTANT This product should be installed in a restricted access location where a...

Страница 17: ...et the following special conditions for safe use The device must be installed in a suitable enclosure Components must not be substituted for non Siemens parts The device must not be disconnected unless the power has been turned off or the area is known to be non hazardous The device must be appropriately connected to safety Earth upon installation Note For further details of the device s complianc...

Страница 18: ...for some convectional airflow Forced airflow is not required However any increase in airflow will result in a reduction of ambient temperature and improve the long term reliability of all equipment mounted in the rack space Note For detailed dimensions of the device with either DIN rail or panel hardware installed refer to Dimension Drawings Page 27 2 3 1 Mounting the Device on a DIN Rail The RUGG...

Страница 19: ...e The adapter features a sliding release with a slot at the bottom for a flathead screwdriver 1 1 2 1 3 2 1 DIN Rail 2 DIN Rail Adapter Figure 2 1 Mounting the Device to a DIN Rail 2 Insert a flathead screwdriver into the slot of the sliding release and move it down 3 Push the device against the bottom of the DIN rail then let go of the sliding release to latch the device 10 RUGGEDCOM RS940G Insta...

Страница 20: ...ng the bottom of the device away from the DIN rail 3 Lift the device off the DIN rail 2 3 2 Mounting the Device to a Panel For panel installations the RUGGEDCOM RS940G can be equipped with panel adapters pre installed on the top and bottom of the chassis The adapters allow the device to be attached to a panel using screws To mount the device to a panel do the following 1 Prepare mounting holes in ...

Страница 21: ... is closed when the unit is powered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM RUGGEDCOM RS940G One common application for this relay is to signal an alarm if a power failure occurs For more informa...

Страница 22: ...d transient energy is shunted to the Surge Ground terminal In cases where users require the inputs to be isolated from ground remove the ground braid between Surge and Chassis Ground Note that all line to ground transient protection circuitry will be disabled IMPORTANT Siemens requires the use of external surge protection in VDSL applications where the line may be subject to surges greater than th...

Страница 23: ...amage to the power supply may occur NOTICE Electrical hazard risk of damage to equipment Before testing the dielectric strength HIPOT in the field remove the braided ground cable connected to the surge ground terminal and chassis ground This cable connects transient suppression circuitry to chassis ground and must be removed in order to avoid damage to transient suppression circuitry during testin...

Страница 24: ... the negative wire from the power source to the negative neutral N terminal on the terminal block 3 Using a braided wire or other appropriate grounding wire connect the surge ground terminal to the chassis ground connection The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 4 Connect the ground terminal on the power sour...

Страница 25: ...e following 1 Connect the positive wire from the power source to the positive terminal on the terminal block 1 3 2 4 1 Positive Terminal 2 Negative Terminal 3 Surge Ground Terminal 4 Braided Ground Cable Figure 2 6 Terminal Block Wiring Single DC Power Supply Inputs 16 RUGGEDCOM RS940G Installation Manual 01 2021 C79000 G8976 1036 07 ...

Страница 26: ...o the negative terminal on the terminal block 3 Using a braided wire or other appropriate grounding wire connect the surge ground terminal to the chassis ground connection The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 4 Connect the ground terminal on the power source to the chassis ground terminal on the device RUGG...

Страница 27: ...Installing the Device 2 5 2 Connecting Low DC Power 18 RUGGEDCOM RS940G Installation Manual 01 2021 C79000 G8976 1036 07 ...

Страница 28: ...S232 Serial Console Port Connect a PC or terminal directly to the serial console port to access the boot time control and RUGGEDCOM RUGGEDCOM ROS console interface IMPORTANT The serial console port is intended to be used only as a temporary connection during initial configuration or troubleshooting and should only be used in a safe area as defined by IEC 60079 0 Edition 6 0 The serial console port...

Страница 29: ...e device to a management switch and access the RUGGEDCOM RUGGEDCOM RS940G console and Web interfaces via the device s IP address The factory default IP address for the RUGGEDCOM RS940G is https 192 168 0 1 For more information about available ports refer to Communication Ports Page 21 3 2 Configuring the Device Once the device is installed and connected to the network it must be configured All con...

Страница 30: ...Each communication port type has a specific place in the RUGGEDCOM RS940G chassis 1 2 1 Ports 1 to 6 2 Ports 7 to 8 Figure 4 1 Port Assignment Port Type 1 to 6 Copper Gigabit Ethernet Ports 10 100 1000Base TX 7 to 8 Fixed SFP or GBIC Gigabit Ethernet Ports 1000Base SX or 1000Base LX 4 1 Copper Ethernet Ports The RUGGEDCOM RS940G supports several 10 100 1000Base TX Ethernet ports that allow connect...

Страница 31: ...he port 1 2 1 Speed LED 2 Link Activity LED Figure 4 2 RJ45 and FastConnect RJ45 Port LEDs LED State Description Yellow The port is operating at 1000 Mbps Speed Off The port is operating at 10 or 100 Mbps Yellow Solid Link established Yellow Blinking Link activity Link Activity Off No link detected The following is the pin out for the RJ45 male connectors 1 8 Figure 4 3 RJ45 Ethernet Port Pin Conf...

Страница 32: ...nd matched to establish a proper link 2 1 1 Tx Connector 2 Rx Connector Figure 4 4 LC Port 2 1 1 Tx Connector 2 Rx Connector Figure 4 5 SC Port For specifications on the available fiber optic Ethernet ports refer to Fiber Optic Ethernet Port Specifications Page 26 4 3 SFP Transceivers The RUGGEDCOM RS940G features four Small Form Factor Pluggable SFP transceiver sockets which are compatible with a...

Страница 33: ...ility as a result of performance issues related in whole or in part to third party components SFP Transceiver Order Code Speed Mbit s Mode a Nominal Distance km RUGGEDCOM SFP1122 1SX 6GK6000 8FG51 0AA0 1000 MM 0 5 RUGGEDCOM SFP1132 1LX10 6GK6000 8FG52 0AA0 1000 SM 10 RUGGEDCOM SFP1132 1LX25 6GK6000 8FG53 0AA0 1000 SM 25 RUGGEDCOM SFP1132 1LX40 6GK6000 8FG57 0AA0 1000 SM 40 RUGGEDCOM SFP1132 1LX70 ...

Страница 34: ...sumption varies based on configuration Non Hazardous Environments Input Range Power Supply Type Minimum Maximum Internal Fuse Rating a b Isolation Maximum Power Consumption c 88 VDC 300 VDC 3 15 A T 4 kVAC 18 W HI 85 VAC 264 VAC 3 15 A T 5 5 kVDC 18 W 24 VDC 10 VDC 36 VDC 3 15 A T 1 5 kVDC 18 W 48 37 VDC 72 VDC 3 15 A T 1 5 kVDC 18 W a F denotes fast acting fuse b T denotes time delay fuse c Power...

Страница 35: ...tandard c TIA EIA T568A B Maximum Distance d 100 m 328 ft Isolation e 1 5 kV a Auto negotiating b Shielded or unshielded c Auto crossover and auto polarity d Typical distance Dependent on the number of connectors and splices e RMS 1 minute 5 5 Fiber Optic Ethernet Port Specifications The following details the specifications for fiber Ethernet ports that can be ordered with the RUGGEDCOM RS940G Not...

Страница 36: ...of patches and splices Consult a Siemens sales associates when determining maximum segment distances 5 6 Operating Environment The RUGGEDCOM RS940G is rated to operate under the following environmental conditions Ambient Operating Temperature ab 40 to 85 C 40 to 185 F Ambient Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity c 5 to 95 Maximum Altitude 2000 m 6562 ft a Measured f...

Страница 37: ...Technical Specifications 5 8 Dimension Drawings 99 06 7 87 187 96 221 5 65 13 83 54 116 59 Figure 5 1 Overall Dimensions 28 RUGGEDCOM RS940G Installation Manual 01 2021 C79000 G8976 1036 07 ...

Страница 38: ... Specifications 5 8 Dimension Drawings 1 13 64 141 63 101 60 89 59 183 89 1 SFP Port Reference Figure 5 2 Panel and DIN Rail Mount Dimensions RUGGEDCOM RS940G Installation Manual 01 2021 C79000 G8976 1036 07 29 ...

Страница 39: ...Technical Specifications 5 8 Dimension Drawings 30 RUGGEDCOM RS940G Installation Manual 01 2021 C79000 G8976 1036 07 ...

Страница 40: ...ol Equipment Industrial Products CAN CSA C22 2 No 213 16 Nonincendive Electrical Equipment for Use in Class I and II Division 2 and Class III Divisions 1 and 2 Hazardous Classified Locations Bi National Standard with ANSI ISA 12 12 01 2016 UL 916 Standard for Energy Management Equipment ANSI ISA 12 12 01 2015 Non Incendive Electrical Equipment for Use in Class I and II Division 2 and Class III Div...

Страница 41: ...to the Restriction of Hazardous Substances EN 55022 Information Technology Equipment Radio Disturbance Characteristics Limits and Methods of Measurement The device is marked with a CE marking and can be used throughout the European community A copy of the CE Declaration of Conformity is available from Siemens AG For contact information refer to Contacting Siemens Page vii 6 1 3 FDA CDRH This devic...

Страница 42: ...s designed and manufactured using a certified ISO International Organization for Standardization quality program that adheres to the following standard ISO 9001 2015 Quality management systems Requirements 6 1 7 ACMA This device meets the requirements of the following Australian Communications and Media Authority ACMA standards under certificate ABN 98 004 347 880 Radiocommunications Compliance La...

Страница 43: ... available online at https support industry siemens com cs ww en view 109738831 6 2 EMC and Environmental Type Tests The RUGGEDCOM RS940G has passed the following EMC and environmental tests IEC 61850 3 Type Tests Test Description Test Levels Severity Levels Enclosure Contact 8 kV 4 IEC 61000 4 2 ESD Enclosure Air 15 kV 4 IEC 61000 4 3 Radiated RFI Enclosure Ports 20 V m x Signal Ports 4 kV 2 5 kH...

Страница 44: ...ommon 1 kV differential mode 1 MHz 3 IEC 61000 4 12 Damped Oscillatory AC Power Ports 2 5 kV common 1 kV differential mode 1 MHz 3 Signal Ports 30 V Continuous 300 V for 1 s 4 IEC 61000 4 16 Mains Frequency Voltage DC Power Ports 30 V Continuous 300 V for 1 s 4 IEC 61000 4 17 Ripple on DC Power Supply DC Power Ports 10 3 Signal Ports 2 kVAC Fail Safe Relay output DC Power Ports 2 kV Dielectric Str...

Страница 45: ...0 1 Oscillatory AC Power Ports 2 5 kV common and differential mode 1 MHz Signal Ports 5 kV Failsafe Relay DC Power Ports 5 kV HV Impulse AC Power Ports 5 kV Signal Ports 2 kVAC Failsafe Relay DC Power Ports 1 5 kVDC C37 90 Dielectric Strength AC Power Ports 2 kVAC Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 600...

Страница 46: ...ttps www siemens com ruggedcom Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...

Отзывы: