Certification
6.2 EMC and Environmental Type Tests
Description
Test Levels
Signal Ports
5 kV (Fail-Safe Relay Output)
DC Power Ports
5 kV
HV Impulse
AC Power Ports
5 kV
Signal Ports
2 kV
DC Power Ports
2 kV
Dielectric
Strength
AC Power Ports
2 kV
Damped Os-
cillatory Mag-
netic Field
Enclosure Ports
100 A/m
Environmental Type Tests
Test
Description
Test Levels
Severi-
ty Level
IEC
60068-2-1
Cold Temperature
Test Ad
-40 °C (-40 °F), 16 Hours
IEC
60068-2-2
Dry Heat
Test Bd
85 °C (185 °F), 16 Hours
IEC
60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (non-condensing),
55 °C (131 °F), 6 cycles
IEC
60068-21-1
Vibration
2g @ 10-150 Hz
IEC
60068-21-2
Shock
30 g @ 11 ms
IEC
60068-2-78
Humidity (Damp
Heat, Steady State)
Test Cab
10 days @ 55 °C (131 °F)
and 93% Relative Humidity
IEC
60068-2-14
Change of Temperature
Test Nb
5 Cycles, -40 to 85°
C (40 to 185° F)
IEC
60255-21-2
Bump
10 g @ 16 ms
Class 1
IEC
60255-21-3
Seismic
Method A, Class 2
Class 1
Military Standard Tests
Test
Description
Test Levels
MIL-STD-901D
Shock (Hard-Mounted)
Grade A, Equipment Class
I, Shock Type A Equipment
MIL-STD-167-1
Vibration
Type I (4-33 Hz)
MIL-STD-461E
Electromagnetic Interference
CE101, CE102, CS101, CS114, CS115,
CS116, RE101, RE102, RS101, RS103
MIL-STD-1399
Magnetic Field – DC
Magnetic Exposure
Section 070, Part 1
MIL-STD-810F
Low Pressure Altitude Storage,
Low Pressure Altitude Opera-
tional, High Temperature Stor-
age, High Temperature Opera-
Method 500 Series Procedures
36