Technical support
B.3 Notes on the use of third-party modules
SIMATIC IPC527G
106
Operating Instructions, 03/2019, A5E45491226-AA
Problem
Possible cause
Possible remedy
USB device not responding
The USB ports are not correctly
supported.
•
Turn on USB Legacy Support for mouse and
keyboard.
•
For other devices, you need the USB device
drivers for the required operating system.
"chkdsk" is not functioning
EWF (Enhanced Write Filter) has
been activated. The "chkdsk"
command is not supported if the
EWF has been activated.
Deactivate the EWF or use an alternative method to
"chkdsk".
B.3
Notes on the use of third-party modules
Problem
Possible cause
Possible remedy
The device
crashes during
startup
•
Redundant I/O addresses
•
Redundant hardware interrupts
and/or DMA channels
•
Fluctuation of signal frequencies
or levels
•
Different pin assignment
Check your computer configuration:
•
If the computer configuration corresponds to the delivery
state, contact your technical support team.
•
If the configuration has changed, restore the factory state.
To do this, remove the third-party modules and restart the
device. If the error no longer occurs, the third-party module
being used was the cause of the fault. Replace the thrid-
party module with a Siemens module or contact the module
supplier.
If the device still crashes, contact your technical support team.
•
Insufficient output of an external
power supply, e.g. UPS
•
Use a higher capacity power supply
The device does
not start up or
switches off im-
mediately
•
A counter voltage is fed into the
device by connected or installed
third-party components
Clarify the following with the supplier of the component:
•
The component can be operated without an external power
supply.
•
The component can be reconfigured so that it only uses the
external power supply or that of the device.