Technical specifications
8.8 Active Management Technology (AMT)
SIMATIC IPC427E
134
Operating Instructions, 09/2017, A5E37454814-AB
Settings in the MEBx
1.
Use the arrow keys to select "MEBx" and confirm with the <Enter> key.
2.
Select "MEBx Login".
3.
Enter the default password "admin".
Change the password. The new password must comprise:
–
At least eight characters
–
At least one upper case letter
–
At least one lower case letter
–
At least one number
–
At least one special character (! @ # $ % ^ & *)
–
The underscore "_" and space characters are valid in the string but do not increase the
complexity of the password.
Note
If the password is no longer available, you must reset the Intel® AMT to the default
settings, see Resetting the Intel® AMT to the default settings and disabling AMT
(Page 135).
Backup the password to protect it against loss.
4.
Switch to the "Intel (R) AMT Configuration" submenu and enable "Manageability Feature
Selection".
5.
Switch to the "Intel(R) ME General Settings" submenu and enable access via the network
with "Activate Network Access".
6.
Confirm the dialogs that appear with "Y".
Drivers are automatically installed once as required in the subsequent restart.