Overview
1.1 Product description
SIMATIC IPC427E
Operating Instructions, 09/2017, A5E37454814-AB
11
Basic data
Drives and storage media
CFast card
Can be used optionally as boot drive or additional data memory.
•
2 GB
•
4 GB
•
8 GB
•
16 GB
•
30 GB
Hard disk
2.5", ≥ 320 GB, SATA (optional)
SSD (Solid State Disk)
2.5", ≥ 80 GB SATA (optional)
USB stick
External, can be connected via USB interface
Ports
Serial
COM1 / COM2 (RS 232, RS 422, RS 485 configurable), optional
Graphics
2 x DisplayPort DPP (DVI via DP++ to DVI adapter possible)
USB
4 × USB 3.0, simultaneous operation of max. 2 x high current ports,
backward compatible with USB 2.0/1.1
Ethernet
2 × (3 x optional) RJ45 (10/100/1000 Mbps), teaming-capable
Keyboard, mouse
Connected via external USB port
Extended device functions
Temperature monitoring
•
When permitted temperature range is exceeded
•
Warnings can be analyzed by application program (local, via LAN)
Watchdog
•
Monitoring function for program execution
•
Restart can be parameterized in the event of a fault
•
Warnings can be analyzed by application program (local, via LAN)
LED display
4 LEDs for displaying system statuses; 3 of these can be freely pro-
grammed by the user
Transient voltage interruption Up to 15 ms buffer time at full load
Buffer memory
512 KB optional
TPM
Integrated Trusted Platform Module, optional, according to TPM 2.0
standard