Technical specifications
5.5 Ambient conditions
IFP2200 INOX MT ETH
38
Compact Operating Instructions, 03/2018, A5E42185570-AA
Testing mechanical ambient conditions
The table below provides information on the type and scope of tests for mechanical ambient
conditions.
Tested for
Test standard
Comments
Vibrations
Vibration test in accordance
with IEC 60068, part 2-6
(sinusoidal)
Type of vibration:
Frequency cycles at a rate of change of
1 octave/minute.
10 ... 58 Hz, constant amplitude 3.5 mm
58 ... 200 Hz, constant acceleration 1 g
Vibration duration:
10 frequency cycles per axis in each of the three
mutually vertical axes
Shock
Shock test in accordance
with IEC 60068, Part 2-27
Type of shock: Half-sine
Severity of shock:
Peak value 15 g, duration 11 ms
Direction of shock:
3 shocks in ± direction of axis in each of the three
axes vertical to each other
Shock pulses within the specified range can be transferred to the display but do not impact
the functionality of the device.
Climatic ambient conditions
The following table shows the climatic ambient conditions for operation of the device.
Ambient conditions
Permitted range
Comments
Temperature
•
Vertical mounting
0 ... 45 °C (landscape format)
0 ... 40 °C (portrait format)
•
Mounting at an angle 0 ... 40 °C (landscape format)
0 ... 35 °C (portrait format)
Slope angle max. 35°
Relative humidity
10 ... 90 %, no condensation at the rear of
the device
Atmospheric pressure,
operation elevation
1140 to 795 hPa
Corresponds to an elevation
of -1000 to 2000 m
Pollutant concentration SO
2
: < 0.5 vpm;
Relative humidity < 60 %,
no condensation at the rear of the device
Test: 10 cm
3
/m
3
; 10 days
H
2
S: < 0.1 vpm;
Relative humidity < 60 %,
no condensation at the rear of the device
Test: 1 cm
3
/m
3
; 10 days
Note the information in section "Safety instructions and further information (Page 10)" and
the information on the mounting positions:
●
Permitted mounting positions of the built-in units (Page 14)