Data Blocks/Error Lists
C-21
FM 452 Electronic Cam Controller
C79000-G7076-C452-04
Class 7: Cam Data Errors
The diagnostic interrupt is triggered only when there is an error in the system data
block (SDB).
No.
Meaning
Diagnostic
Interrupt
1
Hardware interrupt not permitted
Yes
Cause
You want to specify a hardware interrupt for a cam with
a cam number > 7.
2
Bad track number
Yes
Cause
The track number is outside the range 0 to 31.
3
Bad cam start
Yes
Cause
The cam start is outside the travel range
(-100m...+100m or -1000m...+1000m).
Rotary axis: The cam start is < 0 and/or higher than the
end of the rotary axis.
4
Bad cam end
Yes
Cause
The cam end is outside the travel range
(-100m...+100m or -1000m...+1000m) .
The cam is at least one pulse long.
Rotary axis: The cam end is < 0 and/or higher than the
end of the rotary axis.
5
Bad activation time
Yes
Cause
The activation time is < 0
µ
s. The maximum time
depends on the number of cams: (see Section 8.9,
page 8-26).
6
Bad lead time
Yes
Cause
The lead time is < 0
µ
s. The maximum time depends on
the number of cams: (see Section 8.9, page 8-26).
50
Too many cam records
Yes
Cause
You wanted to enter more cam records than is possible
with this number of cams.
51
Axis in operation
Yes
Cause
You wanted to enter cam records while the cam
controller is active.
52
Parameters not set for the axis
Yes
Cause
You want to enter cam data although not machine data
are active yet.
Содержание SIMATIC FM 452
Страница 8: ...Contents viii FM 452 Electronic Cam Controller C79000 G7076 C452 04 ...
Страница 14: ...Product Overview 1 6 FM 452 Electronic Cam Controller C79000 G7076 C452 04 ...
Страница 28: ...Installing and Removing the FM 452 3 2 FM 452 Electronic Cam Controller C79000 G7076 C452 04 ...
Страница 36: ...Wiring the FM 452 Electronic Cam Controller 4 8 FM 452 Electronic Cam Controller C79000 G7076 C452 04 ...
Страница 38: ...Installing the Software 5 2 FM 452 Electronic Cam Controller C79000 G7076 C452 04 ...
Страница 62: ...Programming the FM 452 6 24 FM 452 Electronic Cam Controller C79000 G7076 C452 04 ...
Страница 68: ...Putting the FM 452 into Operation 7 6 FM 452 Electronic Cam Controller C79000 G7076 C452 04 ...
Страница 130: ...Settings 9 32 FM 452 Electronic Cam Controller C79000 G7076 C452 04 ...
Страница 140: ...Encoders 10 10 FM 452 Electronic Cam Controller C79000 G7076 C452 04 ...
Страница 146: ...Diagnostics 11 6 FM 452 Electronic Cam Controller C79000 G7076 C452 04 ...
Страница 162: ...Samples 12 16 FM 452 Electronic Cam Controller C79000 G7076 C452 04 ...
Страница 168: ...Technical Specifications A 6 FM 452 Electronic Cam Controller C79000 G7076 C452 04 ...
Страница 174: ...Connection Diagrams B 6 FM 452 Electronic Cam Controller C79000 G7076 C452 04 ...
Страница 200: ...Data Blocks Error Lists C 26 FM 452 Electronic Cam Controller C79000 G7076 C452 04 ...