Connecting Cables
B.1 RS 232C interface of the CP 340–RS 232C
PtP coupling and configuration of CP 340
Manual, 04/2011, A5E00369892-03
169
RS 232C connecting cables (S7 (CP 340) - CP 523)
The figure below illustrates the connecting cable for a point-to-point connection between a
CP 340 and a CP 523.
For the connecting cables you will require the following female/male connectors
●
At the CP 340 end: 9-pin D-sub socket contact with screw interlock
●
At communication partner: 25-pin sub D male connector with screw-locking
&3
5['7['
7['5['
576&76
&76576
'65'75
'75'65
*1'*1'
/,<&<[
&RPPXQLFDWLRQSDUWQHU
5HFHLYHU
5HFHLYHU
6HQGHU
6HQGHU
(QFORVXUHVKLHOG
(QFORVXUHVKLHOG
&DEOHW\SH
Figure B-4
RS 232C Connecting Cable CP 340 - CP 523