Configuring
Application Module FM 458 - User Manual
4-15
6DD1904-0AE0 Edition 12.2001
•
Telegram
runtime:
s
36
6.
µ
•
All of the telegrams are sent immediately one after the other.
•
For instance, for a selected bus cycle time of 0.8 ms, the SL master
can transfer
– one double word each to a max. of 124 slaves/transceiver, or
– 4 double words each to a max. of 31 slaves/transceiver
The remaining times are intervals where a telegram is not sent (NOP).
•
Master-slave process data transfer:
– up to 200 slaves/transceiver can be addressed with address gaps
– up to 8 double words individually for each slave/transceiver
– own process data for each slave/transceiver
•
Dispatcher transceiver process data transfer:
– up to 200 consecutively addressed transceivers
– up to 8 double words
– the same number of used channels for dispatcher and transceiver
(nodes with a max. number of double words defines the number of
channels for all)
•
Data transfer rate:
11 Mbit/s
•
Bus topology:
Fiber-optic cable ring, each node as
signal
amplifier
•
Max. distance between two nodes:
−
40 m for plastic fiber-optic cables, or
−
300 m for glass fiber-optic cables.
Содержание SIMADYN D FM 458
Страница 2: ...http www bzxindaxin com http www gk world com 全球独家推出 全覆盖型省配线解决方案 ...
Страница 3: ...http www bzxindaxin com http www gk world com ...
Страница 4: ...http www bzxindaxin com http www gk world com ...
Страница 5: ...http www bzxindaxin com http www gk world com ...
Страница 6: ......
Страница 11: ...Definitions 1 2 Application Module FM 458 User Manual 6DD1904 0AE0 Edition 12 2001 ...
Страница 123: ...ESD guidelines 5 4 Application Module FM 458 User Manual 6DD1904 0AE0 Edition 12 2001 ...