Installation
Sicore II Installation and Commissioning Guide
667/HB/52600/000 Issue 2 Unrestricted
51
6.8.1.2. Measure Distance D and Mark Position
Using a measuring wheel or laser measure, determine the position at distance D from the
camera, this will be in line with the centre of the capture zone (see Figure 16)
Figure 16 – Distance D position at edge of road
At this position place an object that will be visible in the Sicore II’s ANPR view (e.g. reflects IR
light), it is recommended to use either a traffic cone (with reflective band) or a reflective
puck (Suggested 3M road 290-W, see Figure 17)
Figure 17 – Reflective Puck – 3M 290-W Road Stud