Commissioning
6.4 Modbus address register
7KT16 energy meter
86
Equipment Manual, 09/2020, 2514284147-04
Energy counters
Modbus measured variables with the function codes 03 and 04
Address
Number
of regis-
ters
Format
Access
Unit
Factor
Measured variable
Hex
Decimal
1B20 6944
4
UINT64
R
Wh
10.0
Total active energy - Import
1B24 6948
4
UINT64
R
Wh
10.0
Total active energy - Export
1B28 6952
4
UINT64
R
varh
10.0
Total reactive energy - Import
1B2C 6956
4
UINT64
R
varh
10.0
Total reactive energy - Export
1B30 6960
4
UINT64
R
VAh
10.0
Total apparent energy
1B34 6964
4
UINT64
R
Wh
10.0
Partial active energy - Import
1B38 6968
4
UINT64
R
Wh
10.0
Partial active energy - Export
1B3C 6972
4
UINT64
R
varh
10.0
Partial reactive energy - Import
1B40 6976
4
UINT64
R
varh
10.0
Partial reactive energy - Export
1B44 6980
4
UINT64
R
VAh
10.0
Partial apparent energy
1B48 6984
4
UINT64
R
Wh
10.0
T1 Active energy - Import
1B4C 6988
4
UINT64
R
Wh
10.0
T1 Active energy - Export
1B50 6992
4
UINT64
R
varh
10.0
T1 Reactive energy - Import
1B54 6996
4
UINT64
R
varh
10.0
T1 Reactive energy - Export
1B58 7000
4
UINT64
R
VAh
10.0
T1 Apparent energy
1B5C 7004
4
UINT64
R
Wh
10.0
T2 Active energy - Export
1B60 7008
4
UINT64
R
Wh
10.0
T2 Active energy - Export
1B64 7012
4
UINT64
R
varh
10.0
T2 Reactive energy - Import
1B68 7016
4
UINT64
R
varh
10.0
T2 Reactive energy - Export
1B6C 7020
4
UINT64
R
VAh
10.0
T2 Apparent energy
Address
Number
of regis-
ters
Format
Access
Unit
Factor
Measured variable
Hex
Decimal
1B98 7064
4
UINT64
R
Wh
10.0
T1 Active energy L1 - Import
1B9C 7068
4
UINT64
R
Wh
10.0
T1 Active energy L1 - Export
1BA0 7072
4
UINT64
R
varh
10.0
T1 Reactive energy L1 - Import
1BA4 7076
4
UINT64
R
varh
10.0
T1 Reactive energy L1 - Export
1BA8 7080
4
UINT64
R
VAh
10.0
T1 Apparent energy L1
1BAC 7084
4
UINT64
R
Wh
10.0
T2 Active energy L1 - Import
1BB0 7088
4
UINT64
R
Wh
10.0
T2 Active energy L1 - Export
1BB4 7092
4
UINT64
R
varh
10.0
T2 Reactive energy L1 - Import
1BB8 7096
4
UINT64
R
varh
10.0
T2 Reactive energy L1 - Export
1BBC 7100
4
UINT64
R
VAh
10.0
T2 Apparent energy L1
1BC0 7104
4
UINT64
R
Wh
10.0
T1 Active energy L2 - Import
1BC4 7108
4
UINT64
R
Wh
10.0
T1 Active energy L2 - Export
1BC8 7112
4
UINT64
R
varh
10.0
T1 Reactive energy L2 - Import
1BCC 7116
4
UINT64
R
varh
10.0
T1 Reactive energy L2 - Export
1BD0 7120
4
UINT64
R
VAh
10.0
T2 Active energy L2 - Import
1BD4 7124
4
UINT64
R
Wh
10.0
T2 Active energy L2 - Export
Содержание Sentron 7KT PAC 1600
Страница 1: ......
Страница 2: ......
Страница 8: ......
Страница 12: ...Introduction 1 5 Qualified personnel 7KT16 energy meter 10 Equipment Manual 09 2020 2514284147 04 ...
Страница 16: ......
Страница 70: ...Description 3 6 Supporting software 7KT16 energy meter 68 Equipment Manual 09 2020 2514284147 04 ...
Страница 80: ...Connection 5 4 Wiring test 7KT16 energy meter 78 Equipment Manual 09 2020 2514284147 04 ...
Страница 98: ......
Страница 106: ...Technical data 8 2 Labels on the enclosure 7KT16 energy meter 104 Equipment Manual 09 2020 2514284147 04 ...
Страница 108: ...Dimensional drawings 9 2 Three phase device 7KT16 energy meter 106 Equipment Manual 09 2020 2514284147 04 ...
Страница 113: ......
Страница 114: ......