6.6.2 Installation
►
Before installing the pump, lubricate the seal with washing-up
liquid.
►
Connect pump to the pump housing
Leaks
►
Ensure that all 4 locking hooks in the pump housing
are attached
Sluggish or blocked fan impeller
►
When the pump is changed, the spacer ring attached
to the motor shaft must be transferred to the new
pump
►
Rotate pump to the left into the pump housing until the catch
engages
►
Tilt container back into base pan
►
Screw stainless steel container to the base pan
►
Screw on base plate and side panels
6.6.3
Removing the slide ring seal
►
Remove circulation pump
►
Loosen fan impeller, locking the rotor with a pen or screwdriver
►
Remove pump housing
►
Remove slide ring seal
6.6.4
Installing the slide ring seal
Sluggish or blocked fan impeller
►
Ensure that the spacer ring is re-attached to the
motor shaft.
►
Press slide ring seal into the pump housing
►
Manually rotate fan impeller firmly onto the motor shaft
►
Attach sealing ring
►
Install circulation pump