815_58300000003806_ara_en_e.doc – 30.01.12
Seite 46 von 67
6.9
Water softening system
6.9.1 Removal
1.
Unscrew outside door, base panel, angle strip and side panels.
2.
Detach the tension cords from the hinge levers
3.
Remove the screws which connect the base pan to the hinge
plates
4.
Unscrew the rinsing tank from the rear panel of the base pan
5.
Disconnect the door cable harness from the plug-and-socket con-
nection in the base pan
6.
Remove electrical connections from the regeneration and drainage
valves
7.
Unscrew the fastening nut which connects the salt dispenser to the
rinsing tank
8.
Extract brine solution out of the storage container with a syringe;
9.
Place appliance on its rear panel
10.
Carefully remove base pan, release the catch on the level sensor
housing and the water softening system
11.
Disconnect the circulation pump with the rubber support from the
base pan
12.
Continue removing the base pan until the water softening system
can be removed from the plug-and-socket connections at the water
inlet and from the level sensor housing
13.
Pull out the reed switch
14.
Take out water softening system
6.9.2 Installation
Please note before and during installation
►
Place the seal on the filler neck of the salt
dispenser
►
Insert sealing rings into the plug-and-socket
connections
►
Put rubber cap on the bearing support in the base
pan for the pump sump
►
Insert the switch rod for actuation of the safety
level switch
1.
Insert water softening system
2.
Engage reed switch
3.
Push base pan onto the tank
4.
Fit the rubber bearing to the circulation pump.
5.
Screw on the fastening nut which connects the salt dispenser to
the rinsing tank
6.
Restore electrical connections to the regeneration and drainage
valves
7.
Connect plug-and-socket connection from the door cable harness
8.
Screw the rinsing tank onto the rear panel of the base pan
9.
Screw the base pan to the hinge plates
10.
Attach the tension cords to the hinge levers
11.
Screw on angle strip, side panels, base panel and outside door