Installation
4.2 Installing / uninstalling the SCALANCE X-400
SCALANCE X-400
22
Compact Operating Instructions, 10/2013, A5E01020054-06
Removing from the S7-300 standard rail
To remove the device, you require a slotted screwdriver with a 5.5 mm wide blade.
Note
When uninstalling the IE Switch X-400, hold it by the backplane and not by the modules,
otherwise the device may be damaged.
To remove the device, follow the steps below:
1.
Remove the covers and the dummy cover.
2.
If media modules are inserted, remove them as well.
First loosen the screw below the labeling strip of the module.
3.
Using a slotted screwdriver with a 5.5 mm wide blade, loosen the two captive screws in
the backplane.
4.
Pull out the lower part of the basic device slightly towards the front and lift it from the S7-
300 standard rail.