4. Wiring
4.1 E-Bus (fig. 4)
The E-Bus (B4+,B3,B2,B1-) must be connected to the
central control panel (
A
) and also to other accessories (
B
).
For additional information see the Control panel installation
manual
4.2 Audio for SAK 52 (fig. 5)
Connect terminals A- and A+ to the central control unit (
E
) (e.g.
WMA 11), and also to other accessories (
D
).
Connect terminals 1 and 2 to the speaker (
C
).
A twisted pair with a minimum diameter of 0.6 mm must be
used to avoid extraneous noise. The length of the audio link
to the central control unit must not exceed 200 m.
5. Close and seal the housing (fig. 6)
1 - Engage the cover in the top retainer (
A
).
2 - Close the cover (
B
).
6. Start-up
6.1 Microphone sensitivity
The sensitivity of the microphone can be set using the
connector (fig. 3 item
E
). Connector closed = max. sensitivity,
connector open = min. sensitivity.
6.2 Speaker volume
The volume of the speaker can be set using the connector
(fig. 3 item
R
). Connector closed = max. volume, connector
open = min. volume.
6.3 Addressing
To enter an address in the remote keypad, simultaneously press
keys
and
and hold for approximately 5 sec.
6.4 Display address
To display the current address of the remote keypad,
simultaneously press keys
and
.
6.5 Test of displays
Simultaneously press keys
and
to activate all LEDs
and the buzzer.
7. Technical data
Supply (12
V
DC
)
From the E-Bus
Power consumption min.
22,5 mA
Power consumption max.
105 mA
Operating temperature
0° C to +55° C
Housing
ABS
Dimensions in mm
H 110 x W 170 x D 32
Safety class
IP 30
Environmental
class II
Weight
250 g