Chapter 6
Certification
RUGGEDCOM RS950G
Installation Guide
32
EMC and Environmental Type Tests
Description
Test Levels
AC Line-to-Line
5 kV
Signal Ports
2 kV
DC Line-to-Line
1.5 kV
Dielectric Strength
AC Line-to-Line
2 kV
Environmental Type Tests
Test
Description
Test Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40 °C (-40 °F), 16 Hours
IEC 60068-2-2
Dry Heat
Test Bd
85 °C (185 °F), 16 Hours
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (non-condensing), 55 °C (131 °F), 6 cycles
IEC 60255-21-1
Vibration
2 g @ 10-150 Hz
IEC 60255-21-2
Shock
30 g @ 11 ms