RUGGEDCOM RS920W
Installation Guide
Chapter 6
Certification
EMC and Environmental Type Tests
33
Test
Description
Test Levels
Severity Levels
AC Power Ports
5 kV
EMC Immunity Type Tests per IEEE 1613
NOTE
The RUGGEDCOM RS920W meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires
error-free and interrupted communications.
Description
Test Levels
Enclosure Contact
± 8 kV
ESD
Enclosure Air
± 15 kV
Radiated RFI
Enclosure Ports
35 V/m
Signal Ports
± 4 kV @ 2.5 kHz
DC Power Ports
± 4 kV
AC Power Ports
± 4 kV
Fast Transient
Earth Ground Ports
± 4 kV
Signal Ports
2.5 kV Common Mode @ 1 MHz
DC Power Ports
2.5 kV Common and Differential Mode @ 1 MHz
Oscillatory
AC Power Ports
2.5 kV Common and Differential Mode @ 1 MHz
Signal Ports
5 kV (Failsafe Relay)
DC Power Ports
5 kV
HV Impulse
AC Power Ports
5 kV
Signal Ports
2 kV (Failsafe Relay)
DC Power Ports
1.5 kV
Dielectric Strength
AC Power Ports
2 kV
Environmental Type Tests
Test
Description
Test Levels
Severity Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40 °C (-40 °F), 16 Hours
IEC 60068-2-2
Dry Heat
Test Bd
85 °C (185 °F), 16 Hours
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (Non-Condensing),
55 °C (131 °F), 6 Cycles
IEC 60255-21-1
Vibration
2 g @ 10 to 150 Hz
Class 2
IEC 60255-21-2
Shock
30 g @ 11 ms
Class 2
Содержание RUGGEDCOM RS920W
Страница 4: ...RUGGEDCOM RS920W Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS920W Installation Guide x Customer Support ...
Страница 32: ...Chapter 4 Communication Ports RUGGEDCOM RS920W Installation Guide 22 Serial Ports ...
Страница 38: ...Chapter 5 Technical Specifications RUGGEDCOM RS920W Installation Guide 28 Dimension Drawings ...
Страница 44: ...Chapter 6 Certification RUGGEDCOM RS920W Installation Guide 34 EMC and Environmental Type Tests ...