Chapter 5
Technical Specifications
RUGGEDCOM RS920W
Installation Guide
24
Failsafe Alarm Relay Specifications
Non-Hazardous Environments
Input Voltage
Power Supply Type
Minimum
Maximum
Internal
Fuse Rating
c
Isolation
Maximum Power
Consumption
d
88 VDC
300 VDC
3.15 A(T)
4 kVAC
10 W
HI
85 VAC
264 VAC
3.15 A(T)
5.5 kVDC
10 W
24
10 VDC
36 VDC
3.15 A(T)
1.5 kVDC
10 W
48
37 VDC
72 VDC
3.15 A(T)
1.5 kVDC
10 W
c
(T) denotes time-delay fuse.
d
Power consumption may vary based on configuration.
Section 5.2
Failsafe Alarm Relay Specifications
Hazardous Environments
Maximum Switching Voltage
Rated Switching Current
Isolation
30 VDC
1 A
80 VDC
30 VAC
0.3 A
1500 V
rms
for 1 minute
Non-Hazardous Environments
Maximum Switching Voltage
Rated Switching Current
Isolation
30 VDC
2 A, 60 W
125 VDC
0.24 A, 30 W
125 VAC
0.5 A, 62.5 W
220 VDC
0.24 A, 60 W
250 VAC
0.25 A, 62.5 W
1500 V
rms
for 1 minute
Section 5.3
Serial Port Specifications
The following details the specifications for serial ports that can be ordered with the RUGGEDCOM RS920W.
Copper Serial Ports
Baud Rate
300 to 230 kbps
Содержание RUGGEDCOM RS920W
Страница 4: ...RUGGEDCOM RS920W Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS920W Installation Guide x Customer Support ...
Страница 32: ...Chapter 4 Communication Ports RUGGEDCOM RS920W Installation Guide 22 Serial Ports ...
Страница 38: ...Chapter 5 Technical Specifications RUGGEDCOM RS920W Installation Guide 28 Dimension Drawings ...
Страница 44: ...Chapter 6 Certification RUGGEDCOM RS920W Installation Guide 34 EMC and Environmental Type Tests ...