background image

Chapter 6

Certification

RUGGEDCOM RS910W

Installation Guide

42

EMC and Environmental Type Tests

Test

Description

Test Levels

Severity Levels

IEC 60068-2-30

Humidity (Damp

Heat, Cyclic)

Test Db

95% (Non-Condensing),

55 °C (131 °F), 6 Cycles

IEC 60255-21-1

Vibration

2 g @ 10 to 150 Hz

Class 2

IEC 60255-21-2

Shock

30 g @ 11 ms

Class 2

Содержание RUGGEDCOM RS910W

Страница 1: ...RUGGEDCOM RS910W Installation Guide 07 2018 RC1031 EN 07 Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 ...

Страница 2: ...nt and or networks They are important components in a holistic industrial security concept With this in mind Siemens products and solutions undergo continuous development Siemens recommends strongly that you regularly check for product updates For the secure operation of Siemens products and solutions it is necessary to take suitable preventive action e g cell protection concept and integrate each...

Страница 3: ...Siemens Address Siemens Canada Ltd Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 856 1995 E mail ruggedcom info i ia siemens com Web https www siemens com ruggedcom ...

Страница 4: ...RUGGEDCOM RS910W Installation Guide iv ...

Страница 5: ...ons 4 1 5 1 Supported Fiber Optic Cables 5 Chapter 2 Installing the Device 7 2 1 General Procedure 8 2 2 Unpacking the Device 8 2 3 Installing the Device in Hazardous Locations 8 2 4 Mounting the Device 9 2 4 1 Mounting the Device on a DIN Rail 10 2 4 2 Mounting the Device to a Panel 10 2 5 Connecting the Antennas 11 2 6 Connecting the Failsafe Alarm Relay 12 2 7 Connecting Power 13 2 7 1 Connecti...

Страница 6: ...4 3 Serial RS232 RS485 RS422 Fiber Ports 27 4 4 4 Connecting Multiple RS485 Devices 28 Chapter 5 Technical Specifications 31 5 1 Power Supply Specifications 31 5 2 Failsafe Alarm Relay Specifications 32 5 3 Copper Ethernet Port Specifications 32 5 4 Fiber Optic Ethernet Port Specifications 33 5 5 Serial Port Specifications 34 5 6 Operating Environment 34 5 7 Mechanical Specifications 34 5 8 Dimens...

Страница 7: ...ssing Documentation Training Customer Support Alerts The following types of alerts are used when necessary to highlight important information DANGER DANGER alerts describe imminently hazardous situations that if not avoided will result in death or serious injury WARNING WARNING alerts describe hazardous situations that if not avoided may result in serious injury and or equipment damage CAUTION CAU...

Страница 8: ...nique mix of IT Telecommunications expertise combined with domain knowledge in the utility transportation and industrial markets allows Siemens to provide training specific to the customer s application For more information about training services and course availability visit https www siemens com ruggedcom or contact a Siemens Sales representative Customer Support Customer support is available 2...

Страница 9: ... Installation Guide Preface Customer Support ix Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community ...

Страница 10: ...Preface RUGGEDCOM RS910W Installation Guide x Customer Support ...

Страница 11: ...luding strong encryption protocols using WPA with TKIP and even WPA2 802 11i with 128 bit AES encryption Static authentication support is provided by WPA PSK For additional centralized control the RUGGEDCOM RS910W also supports IEEE 802 1X RADIUS for wireless user traffic and distributing dynamic encryption keys The RUGGEDCOM RS910W provides a high level of immunity to electromagnetic interference...

Страница 12: ...arsh Environments Immunity to EMI and heavy electrical surges Hazardous Location Certification Class I Division 2 40 to 85 C 40 to 185 F ambient operating temperature no fans 20 AWG Galvanized Steel DIN or panel mounting options provide secure mechanical reliability Optional Conformal coated printed circuit boards Universal Power Supply Options Fully integrated power supply Universal high voltage ...

Страница 13: ... refer to Section 3 1 Connecting to the Device Communication Ports Communication ports in general receive and transmit data as well as provide access to the RUGGEDCOM ROS Web interface For more information about the various ports available refer to Chapter 4 Communication Ports Failsafe Alarm Relay Latches to default state when a power disruption or other alarm condition occurs For more informatio...

Страница 14: ...decommissioned For more information refer to the associated User Guide Recycling and Disposal For environmentally friendly recycling and disposal of this device and related accessories contact a facility certified to dispose of waste electrical and electronic equipment Recycling and disposal must be done in accordance with local regulations Section 1 5 Cabling Recommendations All copper Ethernet p...

Страница 15: ... fiber optic cable types are supported under the stated conditions Distance m Cable Type Wavelength nm Modal Bandwidth MHz km 100Base FX 1000Base SX 10GBase SR 850 200 275 33 OM1 62 5 125 1300 500 2000 850 500 550 82 OM2 50 125 1300 500 2000 850 1500 550 300 OM3 50 125 a 1300 500 2000 850 3500 550 400 OM4 50 125 a 1300 500 2000 a Laser optimized ...

Страница 16: ...Chapter 1 Introduction RUGGEDCOM RS910W Installation Guide 6 Supported Fiber Optic Cables ...

Страница 17: ...n exposure IMPORTANT This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications test results and agency approvals and void the user s authority to operate the equipment IMPORTANT This product should be installed in a restri...

Страница 18: ... assistance Section 2 3 Installing the Device in Hazardous Locations The RUGGEDCOM RS910W is designed to comply with the safety standards for Class I Division 2 hazardous locations where concentrations of flammable gases vapors or liquids may be present as opposed to normal operating environments IMPORTANT The device is certified for installation in hazardous environments as a component only It is...

Страница 19: ...ourrait compromettre l admissibilité à la Classe I Division 2 Section 2 4 Mounting the Device The RUGGEDCOM RS910W is designed for maximum mounting and display flexibility It can be equipped with adapters that allow it to be installed on a 35 mm 1 4 in DIN rail or affixed to a panel IMPORTANT Heat generated by the device is channeled outwards from the enclosure As such it is recommended that 2 5 c...

Страница 20: ...il 2 DIN Rail Bracket 2 Pull the release on the bracket down and slide the device onto the DIN rail Let go of the release to lock the device in position If access to the release is limited use a slotted screwdriver or a similar tool to reach the release Section 2 4 2 Mounting the Device to a Panel For panel installations the RUGGEDCOM RS910W can be equipped with panel adapters pre installed on the...

Страница 21: ...ted 360 around the connection point and up to 90 at the joint for optimal positioning NOTE The RUGGEDCOM RS910W is shipped with two 2 4 GHz dipole antennas NOTE For technical specifications refer to Section 4 3 Wireless Ethernet Ports To connect the antennas do the following 1 Make sure the operating frequency range of each antenna is compatible with the device 2 Align the antenna connector with t...

Страница 22: ...s powered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact NOTE Control of the failsafe relay output is configurable through ROS One common application for this relay is to signal an alarm if a power failure occurs For more information refer to the ROS User Guide for the RUGGEDCO...

Страница 23: ...ecting terminal blocks Equipment must be installed according to applicable local wiring codes and standards All line to ground transient energy is shunted to the Surge Ground terminal In cases where users require the inputs to be isolated from ground remove the ground braid between Surge and Chassis Ground Note that all line to ground transient protection circuitry will be disabled CONTENTS Sectio...

Страница 24: ...ble connects transient suppression circuitry to chassis ground and must be removed in order to avoid damage to transient suppression circuitry during testing NOTE Torque all terminal connections to 0 6 N m 5 lbf in 1 Secure the power terminal block to the device 2 Connect the positive wire from the power source to the positive live L terminal on the terminal block 4 1 2 3 Figure 6 Terminal Block W...

Страница 25: ... from the power source to the chassis groun terminal on the terminal block Section 2 7 2 Connecting Low DC Power RUGGEDCOM RS910W s equipped with 24 or 48 V power supply inputs feature reverse polarity protection and dual power supply inputs allowing the device to accept redundant connections to a single DC power supply To connect a low DC power supply to the device do the following NOTE Torque al...

Страница 26: ...ring Single DC Power Supply Inputs 1 Positive Terminal 2 Negative Terminal 3 Surge Ground Terminal 4 Braided Ground Cable 3 Connect the negative wire from the power source to the negative terminal on the terminal block 4 Optional If a redundant connection is required repeat Step 2 and Step 3 to connect the secondary power inputs ...

Страница 27: ...al 3 Surge Ground Terminal 4 Braided Ground Cable 5 Using a braided wire or other appropriate grounding wire connect the surge ground terminal to the chassis ground connection The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 6 Connect the ground wire from the power source to the chassis groun terminal on the terminal b...

Страница 28: ...Chapter 2 Installing the Device RUGGEDCOM RS910W Installation Guide 18 Connecting Low DC Power ...

Страница 29: ...ected in a non hazardous area or when the device is not energized Console Port Connect a workstation directly to the RS232 serial console port to access the boot time control and RUGGEDCOM ROS console interface The console port provides access to RUGGEDCOM ROS s console interface IMPORTANT The serial console port is intended to be used only as a temporary connection during initial configuration or...

Страница 30: ...nnect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM ROS console and Web interfaces via the device s IP address The factory default IP address for the RUGGEDCOM RS910W is https 192 168 0 1 For more information about available ports refer to Chapter 4 Communication Ports Section 3 2 Configuring the Device Once the device is installed and connected ...

Страница 31: ...nhance its abilities and performance 1 2 3 Figure 11 Port Assignment 1 Ports 1 and 2 2 Ports 3 and 4 3 Port 9 Port Type 1 and 2 Serial Ports 3 and 4 Copper 10 100Base TX or Fiber Optic 100Base FX Ethernet Ports 9 Wireless Antennas CONTENTS Section 4 1 Copper Ethernet Ports Section 4 2 Fiber Optic Ethernet Ports Section 4 3 Wireless Ethernet Ports Section 4 4 Serial Ports ...

Страница 32: ... shock hazard that can result in serious injury LEDs Each port features a Speed and Link Activity LED that indicates the state of the port 1 2 Figure 12 RJ45 Port LEDs 1 Speed LED 2 Link Activity LED LED State Description Yellow The port is operating at 100 Mbps Speed Off The port is operating at 10 Mbps Yellow Solid Link established Yellow Blinking Link activity Link Activity Off No link detected...

Страница 33: ...ly connected and matched to establish a proper link Port Types 2 1 Figure 14 MTRJ Port 1 Tx Connector 2 Rx Connector 2 1 Figure 15 LC Port 1 Tx Connector 2 Rx Connector 2 1 Figure 16 SC Port 1 Tx Connector 2 Rx Connector 2 1 Figure 17 ST Port 1 Tx Connector 2 Rx Connector LEDs Each port features an LED that indicates the link activity state of the port State Description Yellow Solid Link establish...

Страница 34: ...tandard Parameter Mode Notes IEEE 802 11g 54 Mbps WLAN Full Access Point 2 4 GHz ISM IEEE 802 11b 11 Mbps WLAN Client support Backwards compatibility Strong Encryption WPA2 AES CCMP Robust Secure Network RSN Enhanced Encryption WPA TKIP RC4 Temporal keys IEEE 802 11i Basic Encryption WEP RC4 Up to 4 static keys IEEE 802 1x Wireless Authentication Personal or Enterprise PSK or RADIUS Section 4 3 2 ...

Страница 35: ...ide channel NOTE Mexico is included in the Rest of World regulatory domain However channels 1 through 8 are for indoor use only while channels 9 through 11 can be used indoors and outdoors Users are responsible for making sure the channel set configuration complies with the regulatory standards of Mexico Regulatory Domains Channel Identifier Frequency MHz America A EMEA E Japan J Rest of World W 1...

Страница 36: ... Serial RS232 RS485 RS422 RJ45 Ports Section 4 4 3 Serial RS232 RS485 RS422 Fiber Ports Section 4 4 4 Connecting Multiple RS485 Devices Section 4 4 1 Serial RS232 RS485 RS422 DB9 Ports The RS910W can be equipped with serial RS232 RS485 RS422 DB9 ports Each port can be set individually through the RUGGEDCOM ROS operating system to operate in RS232 RS485 or RS422 mode For more information refer to t...

Страница 37: ... following is the pin out description for the RS232 RS485 RS422 RJ45 ports 1 8 Figure 19 RS232 RS485 RS422 RJ45 Serial Console Port Name Pin g RS232 Mode RS485 Mode RS422 Mode 1 h DSR RI RX 2 h DCD 3 i DTR 4 Common Isolated Ground 5 RX RX 6 TX TX RX TX 7 i CTS j 8 i RTS j TX RX TX Shield Chassis Ground g No internal termination is provided h Connected internally i Connected internally j In RS232 m...

Страница 38: ...uplex For reliable continuous communication adhere to the following guidelines To minimize the effects of ambient electrical noise use shielded cabling The correct polarity must be observed throughout a single sequence or ring The number of devices wired should not exceed 32 and total distance should be less than 1219 m 4000 ft at 100 kbps The Common terminals should be connected to the common wir...

Страница 39: ...s Connecting Multiple RS485 Devices 29 1219 m 4000 in 120Ω 10nF 120Ω 10nF 1 2 3 5 5 6 4 Figure 21 Recommended RS485 Wiring 1 RUGGEDCOM RS910W Device 2 Common Isolated Ground 3 Negative 4 Positive 5 Shield to Earth Connected At a Single Point 6 RS485 Devices 32 Total ...

Страница 40: ...Chapter 4 Communication Ports RUGGEDCOM RS910W Installation Guide 30 Connecting Multiple RS485 Devices ...

Страница 41: ...tions Section 5 6 Operating Environment Section 5 7 Mechanical Specifications Section 5 8 Dimension Drawings Section 5 1 Power Supply Specifications NOTE When determining cable lengths make sure the minimum input voltage for the power supply is provided at the power source Hazardous Environments Input Range Power Supply Type Minimum Maximum Internal Fuse Rating a Isolation Maximum Power Consumptio...

Страница 42: ...ption may vary based on configuration Section 5 2 Failsafe Alarm Relay Specifications Hazardous Environments Maximum Switching Voltage Rated Switching Current Isolation 30 VDC 1 A 80 VDC 30 VAC 0 3 A 1500 Vrms for 1 minute Non Hazardous Environments Maximum Switching Voltage Rated Switching Current Isolation 30 VDC 2 A 60 W 125 VDC 0 24 A 30 W 125 VAC 0 5 A 62 5 W 220 VDC 0 24 A 60 W 250 VAC 0 25 ...

Страница 43: ...k add 3 dBm To convert from peak to average subtract 3 dBm Maximum segment length is greatly dependent on factors such as fiber quality and the number of patches and splices Consult a Siemens sales associate when determining maximum segment distances Tx dBm Mode Connector Type Tx λ nm j Cable Type μm Minimum Maximum Rx Sensitivity dBm Rx Saturation dBm Distance km j Power Budget dB 62 5 125 1300 1...

Страница 44: ... Typical Distance km 5 Optical Wavelength nm 850 Cable Size 50 125 or 62 5 125 Section 5 6 Operating Environment The RUGGEDCOM RS910W is rated to operate under the following environmental conditions Ambient Operating Temperature k 40 to 85 C 40 to 185 F Ambient Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity l 5 to 95 Maximum Altitude 2000 m k Measured from a 30 cm 12 in radiu...

Страница 45: ...tion Guide Chapter 5 Technical Specifications Dimension Drawings 35 Section 5 8 Dimension Drawings NOTE All dimensions are in millimeters unless otherwise stated 99 06 187 96 168 66 65 3 116 59 7 87 Figure 22 Overall Dimensions ...

Страница 46: ...Chapter 5 Technical Specifications RUGGEDCOM RS910W Installation Guide 36 Dimension Drawings 13 64 101 6 11 2 78 74 120 65 194 06 83 20 183 90 132 9 Figure 23 Panel and DIN Rail Mount Dimensions ...

Страница 47: ...GGEDCOM RS910W complies CONTENTS Section 6 1 1 CSA Section 6 1 2 FCC Section 6 1 3 FDA CDRH Section 6 1 4 ISED Section 6 1 5 TÜV SÜD Section 6 1 6 RoHS Section 6 1 7 Other Approvals Section 6 1 1 CSA This device meets the requirements of the following Canadian Standards Association CSA standards under certificate 1550963 CAN CSA C22 2 No 60950 1 Information Technology Equipment Safety Part 1 Gener...

Страница 48: ...ction against harmful interference when the equipment is operated in a commercial environment This device generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users wil...

Страница 49: ...in hazardous substances in electrical and electronic equipment China RoHS 2 Administrative Measure on the Control of Pollution Caused by Electronic Information Products A copy of the Material Declaration is available online at https support industry siemens com cs ww en view 109738831 Section 6 1 7 Other Approvals This device meets the requirements of the following additional standards IEEE 1613 I...

Страница 50: ...orts 10 V 3 AC Power Ports 10 V 3 IEC 61000 4 6 Induced Conducted RFI Earth Ground Ports 10 V 3 IEC 61000 4 8 Magnetic Field Enclosure Ports 40 A m Continuous 1000 A m for 1 s IEC 61000 4 11 Voltage Dips and Interrupts AC Power Ports 100 for 5 Periods 100 for 50 Periods Signal Ports 2 5 kV Common Mode 1 MHz 1 kV Differential Mode 1 MHz 3 DC Power Ports 2 5 kV Common Mode 1 MHz 1 kV Differential Mo...

Страница 51: ...res error free and interrupted communications Description Test Levels Enclosure Contact 8 kV ESD Enclosure Air 15 kV Radiated RFI Enclosure Ports 35 V m Signal Ports 4 kV 2 5 kHz DC Power Ports 4 kV AC Power Ports 4 kV Fast Transient Earth Ground Ports 4 kV Signal Ports 2 5 kV Common Mode 1 MHz DC Power Ports 2 5 kV Common and Differential Mode 1 MHz Oscillatory AC Power Ports 2 5 kV Common and Di...

Страница 52: ...e 42 EMC and Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 Non Condensing 55 C 131 F 6 Cycles IEC 60255 21 1 Vibration 2 g 10 to 150 Hz Class 2 IEC 60255 21 2 Shock 30 g 11 ms Class 2 ...