Document No. 129-116 
Installation Instructions 
September 24, 2009 

Page 6 of 12 

Siemens Industry, Inc.

 

Figure 3.  TH 832D Flush Installation.  

 
 
 
 
 

 

NOTE: 

Adapter Base and Plug-in Adapter (2) not 
shown. See Figure 1 for proper installation. 

Figure 4.  TH 180, TH 182, TH 192 Horizontal to Vertical  

Flush Installation. 

 

NOTE: 

Adapter Base and Plug-in Adapter (2) not 
shown. See Figure 1 for proper installation. 

Figure 5.  TH 180, TH 182, TH 192 Horizontal to Vertical  

Surface Installation. 

Содержание Retroline TH 192

Страница 1: ...Acting Celsius Scale NOTES 1 Includes all parts needed for all conversions listed in Table 1 including installations where a large rough in hole must be covered These installations may require an adapter frame 192 308 2 For Retrostat Kits with white cover order the standard kit with W suffix 3 For Retrostat Kits with optional 1 2 inch large exposed setpoint adjustment knob order the standard kit w...

Страница 2: ... for the application 3 Place the multi slotted metal plate into the plastic adapter frame plastic frame may or may not be required Attach the multi slotted plate to the terminal head or the wall using screws and slots shown in Figures 3 through 26 4 Loosely screw adapter base to the multi slotted plate 5 Draw plastic tubing through the multi slotted plate and the adapter base Install the plug in a...

Страница 3: ... rough in holes 2 For replacement of thermostats not listed use the Powers Universal Adapter Kit 192 300 Powerstar Thermostat and Powerstar Thermostat Consult you local Siemens Building Technologies representative for details 3 Place the optional 1 2 inch large setpoint adjustment knob on the shaft protruding through the cover Use either the hex key end of the calibration and cover screw wrench or...

Страница 4: ...nstructions provided with the thermostat in this retrostat kit for the following procedures Thermometer Calibration Changeover Point Adjustment Limit Stop Adjustment Sensitivity Adjustment Thermostat Cooling Heating Calibration Troubleshooting Reference Technical Bulletin Document Number TB 214 TH 192 Adapter Kits 155 231 Figure 1 Typical Thermostat Installation ...

Страница 5: ...hrough the frame and into its respective hole Drive the expander nails to secure the frame in place To uninstall the frame remove the expander nails by turning them counterclockwise 3 Mount the cover over the frame and secure in place by turning each end locking screw five turns counterclockwise Figure 2 TH 192 Installation with Guard NOTE Adapter Frame Adapter Base and Plug in Adapter 2 not shown...

Страница 6: ...llation NOTE Adapter Base and Plug in Adapter 2 not shown See Figure 1 for proper installation Figure 4 TH 180 TH 182 TH 192 Horizontal to Vertical Flush Installation NOTE Adapter Base and Plug in Adapter 2 not shown See Figure 1 for proper installation Figure 5 TH 180 TH 182 TH 192 Horizontal to Vertical Surface Installation ...

Страница 7: ...129 116 Installation Instructions September 24 2009 Siemens Industry Inc Page 7 of 12 NOTE Plug in Adapter 2 not shown See Figure 1 for proper installation Figure 6 Honeywell TO900A TP900A Surface Box Installation ...

Страница 8: ...ion NOTE Adapter Base and Plug in Adapter 2 not shown See Figure 1 for proper installation Figure 8 Honeywell TP910A B Flush Banjo Installation NOTE Adapter Base and Plug in Adapter 2 not shown See Figure 1 for proper installation Figure 9 Honeywell TO91A TP901A B Mortar Joint Installation NOTE Adapter Base and Plug in Adapter 2 not shown See Figure 1 for proper installation Figure 10 Honeywell TO...

Страница 9: ...ter Base and Plug in Adapter 2 not shown See Figure 1 for proper installation Figure 12 Honeywell TP931B Flush Electrical Box Installation NOTE Retainer 2 Adapter Base and Plug in Adapter 2 not shown See Figure 1 for proper installation Figure 13 Honeywell TP970A B Shallow Wall Box with Plaster Ring Installation NOTE Retainer 2 Adapter Base and Plug in Adapter 2 not shown See Figure 1 for proper i...

Страница 10: ...ter Base and Plug in Adapter 2 not shown See Figure 1 for proper installation Figure 16 Johnson T4002 Flush Box Installation NOTE Adapter Base and Plug in Adapter 2 not shown See Figure 1 for proper installation Figure 17 Johnson T400 401 402 Flush Fitting Installation NOTE If the terminal head is too close to the wall surface loop the plastic tubing around the multi slotted plate as shown in Figu...

Страница 11: ...red Adapter Base and Plug in Adapter 2 not shown See Figure 1 for proper installation Figure 20 Robertshaw T15 T16 TP2210 Surface Fitting Installation NOTE Adapter Base and Plug in Adapter 2 not shown See Figure 1 for proper installation Figure 21 Robertshaw T15 T16 TP2210 Dry Wall Installation NOTE Adapter Base and Plug in Adapter 2 not shown See Figure 1 for proper installation Figure 22 Barber ...

Страница 12: ...rkway Buffalo Grove IL 60089 4513 U S A Tel 1 847 215 1000 Your feedback is important to us If you have comments about this document please send them to sbt_technical editor us sbt siemens com Document No 129 116 Printed in U S A Page 12 of 12 NOTE Retainer 2 Adapter Base and Plug in Adapter 2 not shown See Figure 1 for proper installation Figure 23 Barber Colman TK1001 1002 1003 1101 1102 1103 90...

Отзывы: