background image

2/8 

Siemens 

QAX34.1 – Room unit with PPS2 interface 

CA2N1645en_02 

Building Technologies 

 

30 Jun 2009 

Ordering 

When ordering, please specify the quantity, product name and type code. 

Example: 

30 

Room units  

QAX34.1 

Equipment combinations 

The room unit is suitable for use in conjunction with all controllers which incorporate a 
PPS2 room unit interface (e.g. DESIGO RX, DESIGO PX). 

Mechanical design 

The room unit is designed for surface mounting (with knock-outs for cable entry from 
the top or bottom) or for mounting on a recessed conduit box with the cables connected 
from the rear. 

The unit comprises a housing and base unit, connected by releasable snap-fittings.  

The base unit accommodates the screw terminals which have an integrated terminal 
strip.  

The housing accommodates a printed circuit board, room temperature sensor element, 
setpoint adjuster, rocker switch for mode selection and fan speed selection, plug-in 
connectors and a socket for the commissioning and service tool or service terminal.  

Both the housing and base are made of plastic. 

 
 
 
 
 
 
Base unit 
 
 
Housing 

80083

 

 
 
 
 
 
 

80084

Socket for the commissioning 
and service tool or service 
terminal 

 

80166A

 

 

Room temperature display and sequence (heating or cooling) 

 

 
Rocker switch for room temperature setpoint adjustment 

 

Indication of current control mode or current fan speed 

 

 
Rocker switch for mode selection and fan speed 

 
The actual functions of the operator controls and indicators are determined by the con-
troller (based on the selected application and associated parameters). The description 
below covers all possibilities for these items. 
 
The controller control mode can be selected on the basis of occupancy, using the 
rocker switch on the room unit. The same switch can also be used for manual selection 
of up to three fan speeds.  

Operator controls  
and indication 

Note 

Rocker switch for mode 
selection and fan speed 

Содержание QAX34.1

Страница 1: ...it is used in rooms controlled by an individual room control system to mea sure the room temperature and for operation of the room controller The functions of the LCD display are determined by the controller If manual fan speed control is enabled the room unit is suitable for control of a fan coil system It can also be used in conjunction with a DESIGO PXC automation station 1 The room unit incorp...

Страница 2: ...etpoint adjuster rocker switch for mode selection and fan speed selection plug in connectors and a socket for the commissioning and service tool or service terminal Both the housing and base are made of plastic Base unit Housing 80083 80084 Socket for the commissioning and service tool or service terminal 80166A Room temperature display and sequence heating or cooling Rocker switch for room temper...

Страница 3: ...ress the switch once to switch from a display of the current room temperature to a display of the setpoint Each further operation of the or switch raises or lowers the setpoint by 0 5 K or 1 0 F the unit of measurement is determined by the controller The controller also determines the maximum adjustment range allowed In normal operation the following may be displayed depending on the controller co...

Страница 4: ...oom units may be connected to a PXC automation station they are identified by different settings of their address plugs A twisted pair cable is required for the connection to the controller DESIGO RX uses four core cables DESIGO PX uses two core cables see the respec tive installation guides Screening is not required Mounting The room unit is suitable for wall mounting and for mounting on a recess...

Страница 5: ...ce tool initiates a wink command the type of controller connected will be displayed on the room unit For example Controller type Display RXC21 1 RXC30 1 Operating notes During operation and commissioning the LCD display also indicates errors as follows Display Description Error type C No communication with controller for more than 64 s 02 Firmware version e g Version 2 0 D Room temperature sensor ...

Страница 6: ...IGO RXC CA110334 DESIGO RXB RXL CM110381 DESIGO RXA CA2Z3884 DESIGO PX CA110396 Cable type 2 core or 4 core twisted pairs unscreened Connecting cable for service tool Off the shelf max 3 m Housing protection standard Protection standard to EN 60529 IP 30 Protection class Insulation protection class III Ambient conditions IEC 721 Operation Transport Ambient air conditions Class 3K5 Class 2K3 Temper...

Страница 7: ...voltage CP 1 Device supply Data PPS2 pos CP 2 Device supply Data PPS2 neg Bus connection looped to tool socket C 3 With LONWORKS bus DESIGO RXC CLA C 4 With LONWORKS bus DESIGO RXC CLB 5 8 Not used Standard type RJ45 tool socket 1 3206Z01 2 3 45 67 8 With LONWORKS bus DESIGO RXC CLA With LONWORKS bus DESIGO RXC CLB Not used Not used Not used Not used CP Data PPS2 CP Data PPS2 Connection diagram Ex...

Страница 8: ...ns QAX34 1 Room unit with PPS2 interface CA2N1645en_02 Building Technologies 30 Jun 2009 Dimensions 9 5 32 34 4 2 60 80088 90 100 56 60 56 All dimensions in mm 2000 2009 Siemens Switzerland Ltd Subject to change ...

Отзывы: