7 . Enter the IP address and subnet mask.
8. Click
OK
.
In the example, the PC is assigned IP address
192.168.2.199
and subnet mask
255.255.255.0
.
You can now set the web server:
•
IP address: An unused address in subnet, e.g.
192.168.2.10
•
Subnet mask:
255.255.255.0
•
Default gateway: (empty)
•
Preferred DNS server: (empty)
•
Alternate DNS server: (empty)
•
In the example, the subnet has address
192.168.2.x
. Devices must have the
same subnet address to communicate directly (i.e. without a router).
Notes
•
The default gateway and DNS server settings have no meaning for LANs without
router, provided no e-mail is sent within the home network.
•
We recommend using IP addresses from the private range in the home network
(see Section 6.3.1).