![Siemens Nespresso TK911 Скачать руководство пользователя страница 58](http://html.mh-extra.com/html/siemens/nespresso-tk911/nespresso-tk911_repair-instructions_375834058.webp)
9. Insert test finger (D = 5 mm) between the doors of the capsule
infeed, press the “on” button and start coffee brewing process
without capsule.
13. Check function of IR sensor for capsule container
►
Pull out capsule container 10 – 44 mm
►
Empty capsule
displayed?
►
If there is a door gap of 5 mm during a brewing process, the
error message
F8
must be displayed. Coffee cannot be
brewed.
►
Pull out capsule container all the way
►
Check container
displayed?
10. Brew a cappuccino
14. Function of ledge light
►
Place the capsule (Cosi is most suitable) with the membrane
face down in the capsule infeed and start the brewing
process.
►
Is switched on during brewing mode
►
Is switched on during standby
►
Capsule is drawn in, brewing head moves to the brewing
position, appliance heats up to steam temperature, steam is
drawn (10 seconds), appliance cools down to coffee tem-
perature, coffee is drawn (40 ml), capsule is ejected.
15. Function of cup heater PTC
►
Check with your hand whether the cup heater is warming up.
16. Steam out the appliance
11. Draw small cup of coffee
►
Heat up the appliance to steam temperature. Draw steam.
Remove water tank and wait until no more steam comes out
of the nozzle.
►
Place the capsule (Cosi is most suitable) with the membrane
face down in the capsule infeed and start the brewing
process.
►
Wait until
Add water
is displayed, after approx. 20 seconds
Ready
is displayed. The appliance can now be switched off.
►
Coffee is drawn (40 ml), capsule is ejected.
12. Hot water is drawn for approx. 10 seconds until water runs
out evenly
►
Check that the thread of the nozzle body for the frother is not
leaking.
58300000116013_en_a – 21.08.06
Seite 58 von 61